Back to results

Massachusetts Institute of Technology

The use of a novel residuum model to design a variable-impedance transtibial prosthetic socket

Abstract

dc:description.abstract

For people living with limb amputation, the prosthetic socket - the interface between the residuum and prosthesis - is the most critical component. When a socket is uncomfortable, especially due to poor fit, the quality of life for a patient is greatly hindered. However, conventional design of sockets is largely artisan, with limited input of quantitative data. Current computer-aided and manufacturing (CAD/CAM) designs are still not clinically applicable solutions. Due to model identification procedures that employ non patient-specific and incomplete data sets, today's finite element (FE) models of the residuum are not predictive, leading to suboptimal socket designs. As such, there exists a need for a comprehensive biomechanical model of the residuum for the quantitative design and computational evaluation of patient-specific prosthetic sockets. This thesis presents a combined experimental-numerical approach to evaluate and validate a transtibial residuum biomechanical model. The central hypothesis of the work is that a single biomechanical model can predict the large non-linear response at various sites on a residuum under load. To evaluate this hypothesis, a non-linear, two-tissue model was formulated where tissue geometries were defined using MRI data of the residuum. The non-linear viscoelastic material parameters of the model were identified through inverse FEA-based optimization using in-vivo indentation experimental data at four locations. Using optimized model tissue parameters, the mean percentage error (mean absolute error/ maximum experimental force) between the experimental and simulation force-time curves at 14 other locations across the evaluated transtibial residuum was 7 ± 3%. Using this same modeling methodology and a single set of material constants to describe the bulk soft tissue biomechanical response of seven distinct transtibial residual limb models, the average percentage error for indentations at multiple locations across all seven limbs was 7 ± 1%. From these predictive models of residuum limbs, one rigid novel socket and two multimaterial transtibial sockets were designed, fabricated and evaluated through an entirely quantitative, automated and repeatable methodology. In a preliminary clinical investigation, the novel sockets were shown to reduce peak contact pressures at the tibia and fibular head regions on the residuum by significant amounts during standing compared to a conventional socket interface designed and fabricated by a trained prosthetist.

Degree

thesis:*
Department dc:contributor.department
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sengeh, David Moinina
Advisor dc:contributor.advisor
  • Hugh Herr.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/106069
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/106069

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Sengeh, David Moinina. The use of a novel residuum model to design a variable-impedance transtibial prosthetic socket. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/106069