Back to results

Massachusetts Institute of Technology

Optimization of transverse flux motor for utilization in bionic joints

Abstract

dc:description.abstract

Though there have been remarkable advances in powered prosthesis technology over the past decade, design limitations of commercial electric motors are one of the main bottlenecks in meeting critical device requirements, such as minimum range on a single battery charge and acoustic emission restrictions. Traditional motor design focuses on motor development for operation at specific torques and velocities, but a motor design which minimizes the power loss over the torque-velocity profile of a bionic ankle is more precisely what is needed for our application. Considering the design requirement in this way lays the groundwork for a new design framework. Leveraging this problem statement, we herein develop a new motor design process generalizable to all applications requiring a variable but cyclic torque-velocity profile. We present a motor optimization package for cyclic variable torque-velocity motor design and demonstrate its viability in constrained optimization of a transverse flux motor for use in a bionic ankle. We further evaluate and present the intended use of this transverse flux motor for application in bionic joints, along with advantages and design hurdles of the planned system.

Degree

thesis:*
Department dc:contributor.department
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Taylor, Cameron Roy
Advisor dc:contributor.advisor
  • Hugh Herr.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/106047
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/106047

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Taylor, Cameron Roy. Optimization of transverse flux motor for utilization in bionic joints. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/106047