Back to results

Massachusetts Institute of Technology

Extending the reach of anterior segment ophthalmic imaging

Abstract

dc:description.abstract

Eye exams via a slit lamp are critical in screening for conditions such as cataracts, corneal opacities and pterygia early on to avert vision loss. The slit lamp, however, is a purely qualitative optical device that is bulky, expensive, can cause eye discomfort due to light sensitivity. It also requires a trained physician to operate, making it unsuitable for large-scale screening in resource-constrained settings. In this thesis, we propose a spectrum of portable anterior segment imaging solutions that can be operated by minimally trained health workers. On one end, we present a smartphone attachment with minimal optics and no electronic components beyond what is present in the smartphone itself to examine and image the anterior segment of the eye. This cost-effective, easily scalable solution would help extend the reach of anterior segment examination to extremely resource constrained settings, such as mass-screening camps, mobile ophthalmology clinics, war zones etc. On the other end, we propose purely solid-state instrumentation that employs programmable illumination and light steering optics to simulate the motion of a slit on the eye, thereby exhibiting functionality similar to that of a slit lamp with no moving parts. Finally, we discuss potential deployment strategies for two implementations of this technology in the specific cases of two contrasting healthcare systems in India.

Degree

thesis:*
Department dc:contributor.department
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sinha, Shantanu (Shantanu Sanjay)
Advisor dc:contributor.advisor
  • Ramesh Raskar.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/106046
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/106046

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Sinha, Shantanu (Shantanu Sanjay). Extending the reach of anterior segment ophthalmic imaging. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/106046