Back to results

Massachusetts Institute of Technology

An embedded device for real-time noninvasive intracranial pressure estimation

Abstract

dc:description.abstract

Monitoring of intracranial pressure (ICP) is key in many neurological conditions for diagnosis and guiding therapy. Current monitoring methods are highly invasive, limiting their use to the most critically ill patients. Based on a previously developed approach to noninvasive ICP estimation from cerebral blood flow velocity (CBFV) and arterial blood pressure (ABP) waveforms, I have implemented the algorithm on an embedded device (LPC4337 microcontroller) that can produce real-time estimates of ICP from noninvasively-obtained ABP and CBFV measurements. I have also fabricated a medical device prototype complete with peripheral interfaces for ABP and CBFV monitoring hardware and display and recording functionality for clinical use and post-acquisition analysis. The current device produces a mean estimate of ICP once per minute and can perform the necessary computations in 410 ms, on average. Real-time estimates of noninvasive ICP differed from the original batch-mode MATLAB implementation of the algorithm by 0.34 mmHg (RMSE). The contributions of this thesis take a step toward the goal of real-time noninvasive ICP estimation in a variety of clinical settings.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Matthews, Jonathan Martin
Advisor dc:contributor.advisor
  • Thomas Heldt.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/105974
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/105974

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Matthews, Jonathan Martin. An embedded device for real-time noninvasive intracranial pressure estimation. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/105974