{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/105659"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/105659","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Microrid operation strategy for improved recovery and inertial response after large disturbances","abstract":"The electric grid is one of the major achievements of human kind. In the last hundred years it has grown from small clusters of generation and loads, into large networks containing millions of elements and spanning entire continents. Recently, the increasing deployment of distributed generators (DGs) has triggered a grid transformation from a rigid to a flexible and de-centralized structure. Microgrids are an essential element in this transformation because by grouping DGs and loads into controllable units, they can provide a coordinated response to maximize their impact on the grid. Microgrids are inherently different from the larger grid. This thesis shows how by challenging the paradigm of constant frequency and voltage operation, a new strategy can be implemented to achieve an improved response after large disturbances without compromising safety. Large disturbances are commonly encountered in the grid and disrupt the power balance that is required for a reliable operation. If the imbalance is large enough and the proper actions are not taken, then a blackout will occur, affecting millions of people and creating a severe economic impact. To demonstrate the advantages of the proposed operation strategy, two large disturbances are studied: a fault in the distribution network that creates a reactive power imbalance due to induction motor stalling, and a sudden change in generation or consumption that leads to a real power imbalance. In the first part, a framework is created to study fault events and then used to describe a fault recovery strategy that expands the stability region of the system. In the second part, the proposed operation strategy is presented as a new control technique that allows energy to be extracted from the induction motors in the system to achieve an inertial response and provide frequency regulation. All the results are validated using a microgrid experimental set-up that was built as part of this thesis.","abstract_html":"The electric grid is one of the major achievements of human kind. In the last hundred years it has grown from small clusters of generation and loads, into large networks containing millions of elements and spanning entire continents. Recently, the increasing deployment of distributed generators (DGs) has triggered a grid transformation from a rigid to a flexible and de-centralized structure. Microgrids are an essential element in this transformation because by grouping DGs and loads into controllable units, they can provide a coordinated response to maximize their impact on the grid. Microgrids are inherently different from the larger grid. This thesis shows how by challenging the paradigm of constant frequency and voltage operation, a new strategy can be implemented to achieve an improved response after large disturbances without compromising safety. Large disturbances are commonly encountered in the grid and disrupt the power balance that is required for a reliable operation. If the imbalance is large enough and the proper actions are not taken, then a blackout will occur, affecting millions of people and creating a severe economic impact. To demonstrate the advantages of the proposed operation strategy, two large disturbances are studied: a fault in the distribution network that creates a reactive power imbalance due to induction motor stalling, and a sudden change in generation or consumption that leads to a real power imbalance. In the first part, a framework is created to study fault events and then used to describe a fault recovery strategy that expands the stability region of the system. In the second part, the proposed operation strategy is presented as a new control technique that allows energy to be extracted from the induction motors in the system to achieve an inertial response and provide frequency regulation. All the results are validated using a microgrid experimental set-up that was built as part of this thesis.","abstract_has_math":false,"creators":["Elizondo Martinez, Jorge"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["James L. Kirtley, Jr."],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-07-22T22:21:56Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/105659","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["James L. Kirtley, Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Elizondo Martinez, Jorge"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-12-05T19:56:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-12-05T19:56:53Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/105659"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: Ph. D., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2016.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 177-183)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The electric grid is one of the major achievements of human kind. In the last hundred years it has grown from small clusters of generation and loads, into large networks containing millions of elements and spanning entire continents. Recently, the increasing deployment of distributed generators (DGs) has triggered a grid transformation from a rigid to a flexible and de-centralized structure. Microgrids are an essential element in this transformation because by grouping DGs and loads into controllable units, they can provide a coordinated response to maximize their impact on the grid. Microgrids are inherently different from the larger grid. This thesis shows how by challenging the paradigm of constant frequency and voltage operation, a new strategy can be implemented to achieve an improved response after large disturbances without compromising safety. Large disturbances are commonly encountered in the grid and disrupt the power balance that is required for a reliable operation. If the imbalance is large enough and the proper actions are not taken, then a blackout will occur, affecting millions of people and creating a severe economic impact. To demonstrate the advantages of the proposed operation strategy, two large disturbances are studied: a fault in the distribution network that creates a reactive power imbalance due to induction motor stalling, and a sudden change in generation or consumption that leads to a real power imbalance. In the first part, a framework is created to study fault events and then used to describe a fault recovery strategy that expands the stability region of the system. In the second part, the proposed operation strategy is presented as a new control technique that allows energy to be extracted from the induction motors in the system to achieve an inertial response and provide frequency regulation. All the results are validated using a microgrid experimental set-up that was built as part of this thesis."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:title","label":"Title","values":["Microrid operation strategy for improved recovery and inertial response after large disturbances"]}]}],"canonical_facts":{"dc:contributor.advisor":["James L. Kirtley, Jr."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Elizondo Martinez, Jorge"],"dc:date.accessioned":["2016-12-05T19:56:53Z"],"dc:date.available":["2016-12-05T19:56:53Z"],"dc:date.issued":["2016"],"dc:description":["Thesis: Ph. D., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2016.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 177-183)."],"dc:description.abstract":["The electric grid is one of the major achievements of human kind. In the last hundred years it has grown from small clusters of generation and loads, into large networks containing millions of elements and spanning entire continents. Recently, the increasing deployment of distributed generators (DGs) has triggered a grid transformation from a rigid to a flexible and de-centralized structure. Microgrids are an essential element in this transformation because by grouping DGs and loads into controllable units, they can provide a coordinated response to maximize their impact on the grid. Microgrids are inherently different from the larger grid. This thesis shows how by challenging the paradigm of constant frequency and voltage operation, a new strategy can be implemented to achieve an improved response after large disturbances without compromising safety. Large disturbances are commonly encountered in the grid and disrupt the power balance that is required for a reliable operation. If the imbalance is large enough and the proper actions are not taken, then a blackout will occur, affecting millions of people and creating a severe economic impact. To demonstrate the advantages of the proposed operation strategy, two large disturbances are studied: a fault in the distribution network that creates a reactive power imbalance due to induction motor stalling, and a sudden change in generation or consumption that leads to a real power imbalance. In the first part, a framework is created to study fault events and then used to describe a fault recovery strategy that expands the stability region of the system. In the second part, the proposed operation strategy is presented as a new control technique that allows energy to be extracted from the induction motors in the system to achieve an inertial response and provide frequency regulation. All the results are validated using a microgrid experimental set-up that was built as part of this thesis."],"dc:description.degree":["Ph. D."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/105659"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Microrid operation strategy for improved recovery and inertial response after large disturbances"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:56Z"}