Back to results

Massachusetts Institute of Technology

Optimizing registration of complex vascular geometries

Abstract

dc:description.abstract

Advances in imaging, such as coronary angiography, intravascular ultrasound, and optical coherence tomography, can improve procedural success and outcomes for endovascular catheter intervention, such as stent implantation. Yet, these imaging modalities are not universally embraced; and thus, optimization of stent implantation and management of the adverse outcomes remain challenging. This is partially because full adoption of complex imaging awaits methods to reconstruct precise 3D structure of lumen and implanted stent, and to track vascular responses to stent implantation over time in 3D. This thesis creates new methods for reconstruction and registration in 3D by melding disparate imaging modalities, coronary angiography and optical coherence tomography (OCT), that provide different 2D-plane information (longitudinal and cross-sectional) using widely-varied experimental models (static phantom models, preclinical swine model with controlled scenarios of stent implantation in coronary arteries, and clinical unbiased model of stent implantation). A 3D vessel centerline from coronary angiography serves as a fusion path for OCT to reconstruct 3D structures and as a registration path for the reconstructed 3D structures across time. The developed vessel centerline reconstruction method overcame current spatial and temporal alignment challenges, and demonstrated high reproducibility across imaging angles and throughout the cardiac cycle. Structural reconstruction by angiography-OCT fusion was established and improved to account for the cardiac motion, reducing error in estimation of the stent length from 5.5% ± 4.5% with standard fusion to 2.4% ± 2.0%. Time-point registration was accomplished by detecting landmarks that are least affected by the vascular responses - its error, i.e., stent-strut shift from post-implantation to follow-up, was 1.6 mm ± 0.5 mm (9.2% ± 3.0% of the stent length). These methods were validated in a clinical setting and the errors of all methods were within those in the preclinical setting, suggesting potential for clinical applicability.

Degree

thesis:*
Department dc:contributor.department
Harvard--MIT Program in Health Sciences and Technology.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kunio, Mie
Advisor dc:contributor.advisor
  • Elazer R. Edelman.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/104613
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/104613

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Kunio, Mie. Optimizing registration of complex vascular geometries. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/104613