Back to results

Massachusetts Institute of Technology

Design of a constraint device for compliant bodies using quasi-conformal contact surfaces as applied to mouse imaging

Abstract

dc:description.abstract

The purpose of this work is the modeling and prototyping of quasi-conformal constraint contacts and the investigation of their positioning ability for compliant bodies, specifically for the holding of mice in optical imaging setups. The direct application of this work is the restraint of laboratory mice for biological imaging of micron- and submicron-scale biological structures. No existing research has measured the shear stiffness of mouse facial tissue or modeled the effect of quasi-conformal contact constraints on nonlinear materials. The constraint devices and techniques currently available for mice have limitations that have prevented further exploration of their biological structures. The theoretical model, design rationale, and testing results of a prototype device utilizing quasi-conformal constraints are presented in this thesis. This device is capable of restraining anesthetized mice to sub-micron movement in all axes of translation, without additional surgery or discomfort to the mouse. With the findings presented in this thesis, the design of further optimized devices can be made-both for anesthetized and awake mice-enabling further studies in bone marrow and neural activity that are currently impossible. This could ultimately lead to breakthroughs in stem cell and neurobiological research.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Du, Lucy W
Advisor dc:contributor.advisor
  • Martin L. Culpepper.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/104291
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/104291

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Du, Lucy W. Design of a constraint device for compliant bodies using quasi-conformal contact surfaces as applied to mouse imaging. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/104291