Back to results

Massachusetts Institute of Technology

An improved in situ sensing device for freshwater DOM characterization

Abstract

dc:description.abstract

DOC characterization of freshwater is poorly understood at areas of harsh or difficult to access, especially areas like peatland rainforest. In order to figure out the level of DOC transport, an in situ instrument was previously designed to measure the DOC concentration at remote locations. However, the data collected by the instrument is not as meaningful as expected due to the complex environment, high DOC concentration and inner shielding. A new instrument is required to be designed to fulfil the objectives. Like the previous instrument, the new instrument still needs to measure the fluorescence and absorbance data to give an estimation of DOC concentration. There are three LEDs to provide fluorescence measurements, a wideband lamp to provide light for absorbance measurement and a spectrometer to record the resulting spectra. Unlike general in situ fluorometers, the orientation between the excitation source and detector is 90 degrees for the new optical configuration. The new designed optical configuration solves the problem of window obstruction and also successfully prevents the problem of misalignment caused by water turbulence. Furthermore, the instrument also solves the problem of long light path lengths with the new configuration. The instrument was tested to work well in the lab with a range of DOC concentration from 5 ppm to 60 ppm. The recorded data showed a strong positive relationship between fluorescence intensity and concentration of DOC.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Xu, Lu, M. Eng Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Harold F. Hemond.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/104251
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/104251

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Xu, Lu, M. Eng Massachusetts Institute of Technology. An improved in situ sensing device for freshwater DOM characterization. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/104251