{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/103852"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/103852","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Magnetometry with ensembles of nitrogen vacancy centers in bulk diamond","abstract":"This thesis summarizes experiments conducted to develop a high sensitivity vector magnetometer using nitrogen vacancy (NV) centers in a bulk diamond sample. This project began by analyzing the sensitivity of a single NV orientation using a continuous wave electron spin resonance approach. A protocol for determining the diamond's orientation was developed to map vector magnetic field readings in the diamond reference frame to the lab frame. Preliminary vector field measurements and differential vector measurements were performed. Although these showed promising results, significant instrument and ambient magnetic noise limited the achievable sensitivity. A new frequency locking measurement technique was developed to allow for simultaneous measurements between two separate sensors for future differential experiments. This technique provides a host of other benefits including much improved dynamic range and steady-state immunity to fluctuations in linewidth and contrast.","abstract_html":"This thesis summarizes experiments conducted to develop a high sensitivity vector magnetometer using nitrogen vacancy (NV) centers in a bulk diamond sample. This project began by analyzing the sensitivity of a single NV orientation using a continuous wave electron spin resonance approach. A protocol for determining the diamond&#x27;s orientation was developed to map vector magnetic field readings in the diamond reference frame to the lab frame. Preliminary vector field measurements and differential vector measurements were performed. Although these showed promising results, significant instrument and ambient magnetic noise limited the achievable sensitivity. A new frequency locking measurement technique was developed to allow for simultaneous measurements between two separate sensors for future differential experiments. This technique provides a host of other benefits including much improved dynamic range and steady-state immunity to fluctuations in linewidth and contrast.","abstract_has_math":false,"creators":["Teale, Carson (Carson Arthur)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Dirk Englund and Danielle Braje."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-07-22T22:22:09Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/103852","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dirk Englund and Danielle Braje."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Teale, Carson (Carson Arthur)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-02T20:08:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-02T20:08:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/103852"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2015.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 55-57)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis summarizes experiments conducted to develop a high sensitivity vector magnetometer using nitrogen vacancy (NV) centers in a bulk diamond sample. This project began by analyzing the sensitivity of a single NV orientation using a continuous wave electron spin resonance approach. A protocol for determining the diamond's orientation was developed to map vector magnetic field readings in the diamond reference frame to the lab frame. Preliminary vector field measurements and differential vector measurements were performed. Although these showed promising results, significant instrument and ambient magnetic noise limited the achievable sensitivity. A new frequency locking measurement technique was developed to allow for simultaneous measurements between two separate sensors for future differential experiments. This technique provides a host of other benefits including much improved dynamic range and steady-state immunity to fluctuations in linewidth and contrast."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:title","label":"Title","values":["Magnetometry with ensembles of nitrogen vacancy centers in bulk diamond"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dirk Englund and Danielle Braje."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Teale, Carson (Carson Arthur)"],"dc:date.accessioned":["2016-08-02T20:08:38Z"],"dc:date.available":["2016-08-02T20:08:38Z"],"dc:date.issued":["2015"],"dc:description":["Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2015.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 55-57)."],"dc:description.abstract":["This thesis summarizes experiments conducted to develop a high sensitivity vector magnetometer using nitrogen vacancy (NV) centers in a bulk diamond sample. This project began by analyzing the sensitivity of a single NV orientation using a continuous wave electron spin resonance approach. A protocol for determining the diamond's orientation was developed to map vector magnetic field readings in the diamond reference frame to the lab frame. Preliminary vector field measurements and differential vector measurements were performed. Although these showed promising results, significant instrument and ambient magnetic noise limited the achievable sensitivity. A new frequency locking measurement technique was developed to allow for simultaneous measurements between two separate sensors for future differential experiments. This technique provides a host of other benefits including much improved dynamic range and steady-state immunity to fluctuations in linewidth and contrast."],"dc:description.degree":["S.M."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/103852"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Magnetometry with ensembles of nitrogen vacancy centers in bulk diamond"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:09Z"}