Massachusetts Institute of Technology
Long-term, subdermal implantable EEG recording and seizure detection
Abstract
dc:description.abstractEpilepsy is a common chronic neurological disorder that affects about 1% of the world population. Although electroencephalogram (EEG) has been the chief modality in the diagnosis and treatment of epileptic disorders for more than half a century, long-term recordings (more than a few days) can only be obtained in hospital settings. Many patients, however, have intermittent seizures occurring far less frequent. Patients cannot come into the hospital for weeks on end in order for a seizure to be captured on EEG-a necessary prerequisite for making a definitive diagnosis, tailoring therapy, or even establishing the true rate of seizures. This work aims to address this need by proposing a subdermal implantable, eight-channel EEG recorder and seizure detector that has two modes of operation: diagnosis and seizure counting. In the diagnosis mode, EEG is continuously recorded with a 500 Hz bandwidth. This bandwidth is five times higher than typically done to record high-frequency oscillations, which, according to recently published research, may aid in the diagnosis of epilepsy. In the seizure counting mode, the system uses a novel low-power algorithm to track the number of seizures a patient has, providing doctors with a reliable count to help determine medication efficacy. This mode is especially important given the severity of antiepileptic drugs' side-effects. An ASIC that implements the EEG recording and seizure detection algorithm was designed and fabricated in a 0.18 [mu]m CMOS process. The ASIC includes eight EEG channels and was designed to minimize the system's power and size. The result is a power-efficient analog front end that requires 2.75 [mu]W per channel in diagnosis mode and 0.84 [mu]W per channel in seizure counting mode. Both modes have an input-referred noise of approximately 1.1 [mu]Vrms. The seizure detection algorithm has a sensitivity of 98.5%, a false alarm rate of 4.4 per hour, and a detection delay of 9.1 seconds. It consumes only 0.45 [mu]W, which is over an order of magnitude less power than comparable algorithms.
Degree
thesis:*- Department dc:contributor.department
- Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.
- Grantor dc:publisher
- Massachusetts Institute of Technology
- Year dc:date.issued
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Do Valle, Bruno Guimaraes
- Advisor dc:contributor.advisor
-
- Charles G. Sodini.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
- Licence dc:rights.uri
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1721.1/103665
- OAI identifier oai:identifier
- oai:dspace.mit.edu:1721.1/103665