Back to results

Massachusetts Institute of Technology

Precision constraint of deformable bodies for medical imaging applications

Abstract

dc:description.abstract

The purpose of this work is to learn how the performance of a constraint system that interfaces with nonlinear elastic materials such as biological tissue can be predicted by a model. The direct application of this work is the determination of the feasibility of restraining awake and anesthetized mice skulls to submicron levels of movement for biological imaging applications without direct attachment to the skull. A device capable of restricting mouse skull movement to less than a micron in every direction without requiring the rigid attachment of a fixture to the skull would enable studies of bone marrow activity that are not currently possible. No existing work has attempted to determine the performance limits of a constraint system interfacing with nonlinear elastic material. This thesis introduces a model for determining the constraint system performance, and demonstrates how material properties may be tested to determine their relative significance and inclusion in the system model. The theoretical model is applied to the case of an awake mouse to demonstrate that a tissue-interfacing constraint system can only limit movement to hundreds of microns and is not capable of achieving the desired submicron level performance. For the case of an anesthetized mouse, the designed device is tested and achieves the desired sub-micron performance in all three axes for improved imaging capabilities in anesthetized mice.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dias Carlson, Rachel (Rachel A.)
Advisor dc:contributor.advisor
  • Martin L. Culpepper.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/103465
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/103465

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Dias Carlson, Rachel (Rachel A.). Precision constraint of deformable bodies for medical imaging applications. Massachusetts Institute of Technology, 2016. http://hdl.handle.net/1721.1/103465