Back to results

Massachusetts Institute of Technology

A contact force sensor for medical jet injection

Abstract

dc:description.abstract

Medical jet injection, in which a narrow fluid drug stream is propelled into the skin without a needle, was first conceived in the 1940s [1]. However, a major drawback of most injectors is the lack of controllability of jet parameters. Recent work at the BioInstrumentation Laboratory at MIT has resulted in a tunable, high-performance linear Lorentz-force jet injector which allows for careful control of many injection variables. The sensor presented in this thesis further improves the ability to quantify and control contact forces between the injection nozzle and tissue. This sensor uses a three-spoke flexure system with full-bridge strain gauge assemblies mounted on each flexural arm to measure both normal and lateral forces applied to the nozzle. The design, fabrication, calibration, and validation for the sensor are detailed along with results for preliminary tissue injections into ex vivo porcine tissue. These preliminary tests showed higher percent volume delivery to the tissue with an elevated normal force. Under normal forces of 4 to 8 N, the BioInstrumentation Lab's jet injector achieved percent volume delivery of 89.1 ± 5.1%, whereas with normal forces of 0 to 4 N, the percent volume delivery was 68.9 ± 12.7%.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Demas, Nickolas Peter
Advisor dc:contributor.advisor
  • Ian W. Hunter.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/101813
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/101813

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Demas, Nickolas Peter. A contact force sensor for medical jet injection. Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/101813