{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/100669"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/100669","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A high speed wearable system for body coupled communication","abstract":"There are currently no ideal methods by which doctors can read bodily signals detected by implanted devices. Methods are either too high power for long-term implants, such as radio transmission, or pose health threats to the patient, such as connection ports piercing the skin. However, a novel method of transmitting and receiving electronic sensor data is emerging known as body coupled communication (BCC). This method of communication utilizes the inside of the body's low impedance at frequencies on the order of 100 MHz to send signals over that channel and receive the signals at another location on the body. It is also a lower power and more secure wireless option than radio transmission. This thesis presents a 3 Mbps wearable receiver and transmitter system for BCC that was developed from commercially available electrical components and a custom PCB. Both receiver and transmitter are on the same PCB. They share a digital FPGA system, but have separate analog signal conditioning sections on the board.","abstract_html":"There are currently no ideal methods by which doctors can read bodily signals detected by implanted devices. Methods are either too high power for long-term implants, such as radio transmission, or pose health threats to the patient, such as connection ports piercing the skin. However, a novel method of transmitting and receiving electronic sensor data is emerging known as body coupled communication (BCC). This method of communication utilizes the inside of the body&#x27;s low impedance at frequencies on the order of 100 MHz to send signals over that channel and receive the signals at another location on the body. It is also a lower power and more secure wireless option than radio transmission. This thesis presents a 3 Mbps wearable receiver and transmitter system for BCC that was developed from commercially available electrical components and a custom PCB. Both receiver and transmitter are on the same PCB. They share a digital FPGA system, but have separate analog signal conditioning sections on the board.","abstract_has_math":false,"creators":["Rosner, Devon (Devon J.)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Charles G. Sodini."],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-07-22T22:21:51Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/100669","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Charles G. Sodini."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Rosner, Devon (Devon J.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-01-04T20:51:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-01-04T20:51:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/100669"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2014.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 83-84)."]},{"key":"dc:description.abstract","label":"Abstract","values":["There are currently no ideal methods by which doctors can read bodily signals detected by implanted devices. Methods are either too high power for long-term implants, such as radio transmission, or pose health threats to the patient, such as connection ports piercing the skin. However, a novel method of transmitting and receiving electronic sensor data is emerging known as body coupled communication (BCC). This method of communication utilizes the inside of the body's low impedance at frequencies on the order of 100 MHz to send signals over that channel and receive the signals at another location on the body. It is also a lower power and more secure wireless option than radio transmission. This thesis presents a 3 Mbps wearable receiver and transmitter system for BCC that was developed from commercially available electrical components and a custom PCB. Both receiver and transmitter are on the same PCB. They share a digital FPGA system, but have separate analog signal conditioning sections on the board."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M. Eng."]},{"key":"dc:title","label":"Title","values":["A high speed wearable system for body coupled communication"]}]}],"canonical_facts":{"dc:contributor.advisor":["Charles G. Sodini."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Rosner, Devon (Devon J.)"],"dc:date.accessioned":["2016-01-04T20:51:50Z"],"dc:date.available":["2016-01-04T20:51:50Z"],"dc:date.issued":["2014"],"dc:description":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2014.","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 83-84)."],"dc:description.abstract":["There are currently no ideal methods by which doctors can read bodily signals detected by implanted devices. Methods are either too high power for long-term implants, such as radio transmission, or pose health threats to the patient, such as connection ports piercing the skin. However, a novel method of transmitting and receiving electronic sensor data is emerging known as body coupled communication (BCC). This method of communication utilizes the inside of the body's low impedance at frequencies on the order of 100 MHz to send signals over that channel and receive the signals at another location on the body. It is also a lower power and more secure wireless option than radio transmission. This thesis presents a 3 Mbps wearable receiver and transmitter system for BCC that was developed from commercially available electrical components and a custom PCB. Both receiver and transmitter are on the same PCB. They share a digital FPGA system, but have separate analog signal conditioning sections on the board."],"dc:description.degree":["M. Eng."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/100669"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["A high speed wearable system for body coupled communication"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:21:51Z"}