Back to results

Massachusetts Institute of Technology

Improved accuracy in susceptibility-based OEF measurements by mitigation of partial-volume effects via combined magnitude and phase reconstruction

Abstract

dc:description.abstract

Regional quantitative Oxygen Extraction Fraction (OEF) values can only be reliable obtained from blood vessels larger than the acquisition voxel size. Blood vessels beyond this limit produce unreliable measurements due to partial-volume effects. We demonstrate a method for obtaining more reliable OEF measurements beyond this limit by performing a joint reconstruction using both the magnitude and phase of the complex-valued MRI signal. This method is validated both in numerical simulations and on in vivo data. The ability to perform high-quality fetal brain imaging is hampered by motion of the fetus, which can severely degrade image quality. Previously, low-resolution volumetric navigator (vNav) acquisitions have been shown to accurately track motion in human adults and prospectively correct for it. Here, a technique for using vNavs to measure fetal head motion in utero is developed and validated on in vivo data. Parallel Transmission (pTx) improves image quality and patient safety in high-field MRI. Unlike in single-channel MR excitation, an array of multiple excitation coils is used in pTx. However, coupling between these independent coils significantly degrades the power efficiency of the pTx array. Previously, it a decoupling matrix was proposed to solve this inefficiency. In this work, a physical realization of a 4-channel decoupling matrix was constructed and tested.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • McDaniel, Patrick Christopher
Advisor dc:contributor.advisor
  • Elfar Adalsteinsson.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/100637
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/100637

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

McDaniel, Patrick Christopher. Improved accuracy in susceptibility-based OEF measurements by mitigation of partial-volume effects via combined magnitude and phase reconstruction. Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/100637