{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/100605"},"canonical_url":"https://search.dev.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/100605","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Impedance measurement platform for impedimetric biosensor","abstract":"Measuring proteins in blood is particularly common such as in PSA, to determine prostate function and in many other bio-applications. Today this process is inconveniencing in that it requires a lot of blood from the patients for tests to be made. Furthermore it is time consuming and expensive since samples are transferred to a central lab where tests are carried out on optical assays. Using electrical read out methods several measurements can be multiplexed and a differential measurements made. With a differential measurement the precision of the system is improved by cancelling out common mode bio-chemical noise. The multiplexed measurement enables measurement of several analytes. Using the embedded system MAX32600, an electrical impedance meter was designed that measures three impedances simultaneously with accuracy range of up-to 1% and precision of 0.2% of the actual impedance measured from an Impedance analyzer.","abstract_html":"Measuring proteins in blood is particularly common such as in PSA, to determine prostate function and in many other bio-applications. Today this process is inconveniencing in that it requires a lot of blood from the patients for tests to be made. Furthermore it is time consuming and expensive since samples are transferred to a central lab where tests are carried out on optical assays. Using electrical read out methods several measurements can be multiplexed and a differential measurements made. With a differential measurement the precision of the system is improved by cancelling out common mode bio-chemical noise. The multiplexed measurement enables measurement of several analytes. Using the embedded system MAX32600, an electrical impedance meter was designed that measures three impedances simultaneously with accuracy range of up-to 1% and precision of 0.2% of the actual impedance measured from an Impedance analyzer.","abstract_has_math":false,"creators":["Kato, Gerard Bamuturaki"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.","school":null,"contributors":[],"advisors":["Joel Voldman and Brian Brandt."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-07-22T22:22:04Z","subjects":["Electrical Engineering and Computer Science."],"languages":["eng"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1721.1/100605","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joel Voldman and Brian Brandt."]},{"key":"dc:contributor.department","label":"Department","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Kato, Gerard Bamuturaki"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-01-04T19:58:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-01-04T19:58:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/100605"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2015.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Title as it appears in MIT Commencement Exercises program, June 5, 2015: Portable impedimetric biosensor. Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (pages 64-65)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Measuring proteins in blood is particularly common such as in PSA, to determine prostate function and in many other bio-applications. Today this process is inconveniencing in that it requires a lot of blood from the patients for tests to be made. Furthermore it is time consuming and expensive since samples are transferred to a central lab where tests are carried out on optical assays. Using electrical read out methods several measurements can be multiplexed and a differential measurements made. With a differential measurement the precision of the system is improved by cancelling out common mode bio-chemical noise. The multiplexed measurement enables measurement of several analytes. Using the embedded system MAX32600, an electrical impedance meter was designed that measures three impedances simultaneously with accuracy range of up-to 1% and precision of 0.2% of the actual impedance measured from an Impedance analyzer."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M. Eng."]},{"key":"dc:title","label":"Title","values":["Impedance measurement platform for impedimetric biosensor"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joel Voldman and Brian Brandt."],"dc:contributor.department":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Kato, Gerard Bamuturaki"],"dc:date.accessioned":["2016-01-04T19:58:00Z"],"dc:date.available":["2016-01-04T19:58:00Z"],"dc:date.issued":["2015"],"dc:description":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2015.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Title as it appears in MIT Commencement Exercises program, June 5, 2015: Portable impedimetric biosensor. Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (pages 64-65)."],"dc:description.abstract":["Measuring proteins in blood is particularly common such as in PSA, to determine prostate function and in many other bio-applications. Today this process is inconveniencing in that it requires a lot of blood from the patients for tests to be made. Furthermore it is time consuming and expensive since samples are transferred to a central lab where tests are carried out on optical assays. Using electrical read out methods several measurements can be multiplexed and a differential measurements made. With a differential measurement the precision of the system is improved by cancelling out common mode bio-chemical noise. The multiplexed measurement enables measurement of several analytes. Using the embedded system MAX32600, an electrical impedance meter was designed that measures three impedances simultaneously with accuracy range of up-to 1% and precision of 0.2% of the actual impedance measured from an Impedance analyzer."],"dc:description.degree":["M. Eng."],"dc:identifier.uri":["http://hdl.handle.net/1721.1/100605"],"dc:language.iso":["eng"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Impedance measurement platform for impedimetric biosensor"],"dc:type":["Thesis"]},"updated_at":"2026-07-22T22:22:04Z"}