Back to results

Massachusetts Institute of Technology

Photomultiplier tube calibration for the Cubic Meter Dark Matter Time Projection Chamber

Abstract

dc:description.abstract

This thesis concerns measurements I performed on photomultiplier tubes (PMTs) and lenses to be used in the Cubic Meter Dark Matter Time Projection Chamber (DMTPC) experiment. DMTPC is a new generation of detector, which takes the idea of a standard time projection chamber and adds in some additional optical elements, such as CCDs and PMTs. The goal of DMTPC is the directional detection of the dark matter. During the course of my measurements, I characterized both the absolute gains of DMTPC's eight PMTs, as well as the dark currents exhibited by each of the PMTs. Seven of the eight PMTs demonstrated gains on the order of 10 6-10 7, and one PMT did not function at all. Of the seven working PMTs, six of them had dark currents under 10 kHz, and one had an excessively high dark current over 10 kHz. These gain values for the PMTs will give DMTPC the means to measure the Z dimensions of the particle tracks it intends to image, and thus when combined with the information from the CCDs will allow for full track reconstruction. DMTPC will use lenses on their CCD cameras, and I also measured the transparency of these lenses, and discovered that they are opaque below approximately 350nm. These measurements will be essential for DMTPC, because they will provide information about the relative amounts of light the PMTs and CCDs on the detector will register, and thus provide key information for track reconstruction.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Physics.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Burdge, Kevin (Kevin Brian)
Advisor dc:contributor.advisor
  • Peter Fisher.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/100342
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/100342

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Burdge, Kevin (Kevin Brian). Photomultiplier tube calibration for the Cubic Meter Dark Matter Time Projection Chamber. Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/100342