Back to results

Massachusetts Institute of Technology

Design of a single element 3D ultrasound scanner

Abstract

dc:description.abstract

Over the past decade, substantial effort has been directed toward developing ultrasonic systems for medical imaging. With advances in computational power, previously theorized scanning methods such as ultrasound tomography can now be realized. This thesis presents the design, error analysis, and initial image reconstructions from a single element 3D ultrasound tomography system. The system enables volumetric pulse echo or transmission imaging of distal limbs, for applications including: improving prosthetic fittings, monitoring bone density, and characterizing muscle health. The system is designed as a flexible mechanical platform for iterative development of algorithms targeting imaging of soft tissue with bone. The mechanical system independently controls movement of two single element ultrasound transducers in a cylindrical water tank. Each transducer can independently circle about the center of the tank as well as move vertically in depth. High resolution positioning feedback (~1[mu]m) and control enables flexible positioning of the transmitter and the receiver around the cylindrical tank; exchangeable transducers enable algorithm testing with varying transducer frequencies and beam geometries. High speed data acquisition (DAQ) through a dedicated National Instrument PXI setup streams digitized data directly to the host PC. System positioning error has been quantified and is within limits for the desired imaging modality. Imaging of various objects including: calibration objects, phantoms, bone, animal tissue, and human forearm are presented accordingly.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zhang, Xiang, Ph. D. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Brian W. Anthony.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/100306
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/100306

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Zhang, Xiang, Ph. D. Massachusetts Institute of Technology. Design of a single element 3D ultrasound scanner. Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/100306