{"id":{"repo_id":"missouri","oai_identifier":"oai:mospace.umsystem.edu:10355/5855"},"canonical_url":"https://search.dev.ndltd.org/etd/missouri/oai:mospace.umsystem.edu:10355/5855","repository":{"repo_id":"missouri","name":"University of Missouri","base_url":"https://mospace.umsystem.edu/oai/request"},"display":{"title":"Adsorption of water vapor by selected containment aerosols : chlorides and cement dust","abstract":"[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] The macroscopic adsorption isotherms of water vapor on selected containment aerosols of a nuclear reactor such as cesium iodide, cesium chloride, potassium chloride, lithium chloride, and containment concrete dust were studied using a Cahn 2000 electrobalance. The equilibrium adsorption data were obtained at various relative humidities and temperatures. The adsorption isotherm data of water vapor on cesium chloride, potassium chloride, and cesium iodide are of Type III. The adsorption isotherm data of water vapor on containment concrete are Type VIII. The equilibrium adsorption data on all these adsorbents provided a single characteristic curve when correlated according to Polanyi's potential theory. Hysteresis was observed upon desorption for cesium chloride and containment concrete samples. The isosteric heats of adsorption were calculated at different loadings. The isosteric heats of adsorption illustrate that all the adsorbents provided energetically heterogeneous adsorption sites. Jovanovic equation and an empirical equation suggested by Loyalka and Ghosh were used to fit the data over the entire pressure range.","abstract_html":"[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR&#x27;S REQUEST.] The macroscopic adsorption isotherms of water vapor on selected containment aerosols of a nuclear reactor such as cesium iodide, cesium chloride, potassium chloride, lithium chloride, and containment concrete dust were studied using a Cahn 2000 electrobalance. The equilibrium adsorption data were obtained at various relative humidities and temperatures. The adsorption isotherm data of water vapor on cesium chloride, potassium chloride, and cesium iodide are of Type III. The adsorption isotherm data of water vapor on containment concrete are Type VIII. The equilibrium adsorption data on all these adsorbents provided a single characteristic curve when correlated according to Polanyi&#x27;s potential theory. Hysteresis was observed upon desorption for cesium chloride and containment concrete samples. The isosteric heats of adsorption were calculated at different loadings. The isosteric heats of adsorption illustrate that all the adsorbents provided energetically heterogeneous adsorption sites. Jovanovic equation and an empirical equation suggested by Loyalka and Ghosh were used to fit the data over the entire pressure range.","abstract_has_math":false,"creators":["Li, Zhiping, 1967-"],"institution":"University of Missouri--Columbia","degree_name":"Ph. D.","degree_level":"Doctoral","degree_discipline":"Nuclear engineering (MU)","degree_department":null,"school":null,"contributors":[],"advisors":["Ghosh, Tushar K., Dr."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-07-24T03:07:01Z","subjects":[],"languages":["eng","English"],"rights":["Access to files is limited to the University of Missouri--Columbia with SSO login."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.32469/10355/5855"],"render_values":[{"text":"https://doi.org/10.32469/10355/5855","href":"https://doi.org/10.32469/10355/5855","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10355/5855","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ghosh, Tushar K., Dr."]},{"key":"dc:creator","label":"Author","values":["Li, Zhiping, 1967-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-02-24T19:09:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-02-24T19:09:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["University of Missouri--Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Nuclear engineering (MU)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Missouri--Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Access to files is limited to the University of Missouri--Columbia with SSO login."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.32469/10355/5855"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/5855"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file.","Title from title screen of research.pdf file (viewed on May 6, 2009)","Vita.","Thesis (Ph. D.) University of Missouri-Columbia 2006."]},{"key":"dc:description.abstract","label":"Abstract","values":["[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] The macroscopic adsorption isotherms of water vapor on selected containment aerosols of a nuclear reactor such as cesium iodide, cesium chloride, potassium chloride, lithium chloride, and containment concrete dust were studied using a Cahn 2000 electrobalance. The equilibrium adsorption data were obtained at various relative humidities and temperatures. The adsorption isotherm data of water vapor on cesium chloride, potassium chloride, and cesium iodide are of Type III. The adsorption isotherm data of water vapor on containment concrete are Type VIII. The equilibrium adsorption data on all these adsorbents provided a single characteristic curve when correlated according to Polanyi's potential theory. Hysteresis was observed upon desorption for cesium chloride and containment concrete samples. The isosteric heats of adsorption were calculated at different loadings. The isosteric heats of adsorption illustrate that all the adsorbents provided energetically heterogeneous adsorption sites. Jovanovic equation and an empirical equation suggested by Loyalka and Ghosh were used to fit the data over the entire pressure range."]},{"key":"dc:title","label":"Title","values":["Adsorption of water vapor by selected containment aerosols : chlorides and cement dust"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ghosh, Tushar K., Dr."],"dc:creator":["Li, Zhiping, 1967-"],"dc:date.accessioned":["2010-02-24T19:09:45Z"],"dc:date.available":["2010-02-24T19:09:45Z"],"dc:date.issued":["2006"],"dc:description":["The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file.","Title from title screen of research.pdf file (viewed on May 6, 2009)","Vita.","Thesis (Ph. D.) University of Missouri-Columbia 2006."],"dc:description.abstract":["[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI-COLUMBIA AT AUTHOR'S REQUEST.] The macroscopic adsorption isotherms of water vapor on selected containment aerosols of a nuclear reactor such as cesium iodide, cesium chloride, potassium chloride, lithium chloride, and containment concrete dust were studied using a Cahn 2000 electrobalance. The equilibrium adsorption data were obtained at various relative humidities and temperatures. The adsorption isotherm data of water vapor on cesium chloride, potassium chloride, and cesium iodide are of Type III. The adsorption isotherm data of water vapor on containment concrete are Type VIII. The equilibrium adsorption data on all these adsorbents provided a single characteristic curve when correlated according to Polanyi's potential theory. Hysteresis was observed upon desorption for cesium chloride and containment concrete samples. The isosteric heats of adsorption were calculated at different loadings. The isosteric heats of adsorption illustrate that all the adsorbents provided energetically heterogeneous adsorption sites. Jovanovic equation and an empirical equation suggested by Loyalka and Ghosh were used to fit the data over the entire pressure range."],"dc:identifier.doi":["https://doi.org/10.32469/10355/5855"],"dc:identifier.uri":["https://hdl.handle.net/10355/5855"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["University of Missouri--Columbia"],"dc:rights":["Access to files is limited to the University of Missouri--Columbia with SSO login."],"dc:title":["Adsorption of water vapor by selected containment aerosols : chlorides and cement dust"],"dc:type":["Thesis"],"thesis:degree_discipline":["Nuclear engineering (MU)"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["University of Missouri--Columbia"]},"updated_at":"2026-07-24T03:07:01Z"}