Back to results

University of Mississippi

Preparation and Evaluation of Cefuroxime Axetil Gastro-Retentive Floating Drug Delivery System for Improved Delivery via Hot-Melt Extrusion Technology

Abstract

dc:description.abstract

<p>Purpose: The objective of the present study was to develop lipid-based gastro-retentive floating drug delivery system of amorphous Cefuroxime Axetil (CA) to minimize the enzymatic degradation in the gastro intestinal tract utilizing hot-melt extrusion technology for improved absorption. </p><p>Methods: Preliminary studies were performed to select the appropriate lipids. Selected ratios of CA and lipids were extruded using a twin screw hot-melt extruder. Extrudates obtained were milled to obtain floating granules and were further evaluated for drug content, floating strength and micromeritic properties. In vitro drug release studies were performed in 900 mL of simulated gastric fluid (without enzyme) of pH 1.2. The formulations were also studied for their polymorphic nature. Differential scanning calorimetry (DSC) and hot-stage microscopy were used to assess the homogeneity of the formulations and to detect if there is any phase separation during processing and storage. Fourier transform infrared (FTIR) spectroscopy analysis was further used to assess any drug-excipients interactions. </p><p>Results: Solubility studies revealed that CA was highly soluble in Kolliphor® TPGS and Gelucire® 44/14, and solubility increased linearly as the concentration increased. All the extruded granules shofloating lag time of less than 5 seconds and floated for more than 12 h simulated gastric fluid. Optimized formulation was able to give a sustained drug release profile for 12 hours. Micromeritic properties of optimized formulation shogood flow properties compared to the pure drug. Surface characterization revealed that granules had a smooth surface indicating the presence of lipids on the surface. DSC and hot-stage microscopy studies confirmed that there was no phase separation between CA and the excipients. The FTIR studies shothat there was no major interaction between the CA and excipients studied. </p><p>Conclusion: Lipid-based gastro retentive floating drug delivery systems were prepared and shodesired sustained release profiles, which will ensure more complete dissolution of CA with potential improved absorption due to reduced enzymatic degradation and longer residence time in the stomach. </p>

Degree

thesis:*
Name thesis:degree_name
M.S. in Pharmaceutical Science
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Pharmaceutics and Drug Delivery
Year dc:date.available
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lalge, Rahul Madhukar
Contributors dc:contributor
  • Michael A. Repka
  • S. Narasimha Murthy
  • Chalet Tan

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Repository record dc:identifier
https://egrove.olemiss.edu/etd/1341
OAI identifier oai:identifier
oai:egrove.olemiss.edu:etd-2340

Chain of custody

source
Harvested from
University of Mississippi
Base URL
egrove.olemiss.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Lalge, Rahul Madhukar. Preparation and Evaluation of Cefuroxime Axetil Gastro-Retentive Floating Drug Delivery System for Improved Delivery via Hot-Melt Extrusion Technology. Thesis thesis, 2018. https://egrove.olemiss.edu/etd/1341