Back to results

Department of Health Sciences, Lund University

Measurements of knee rotation in vivo - Development and evaluation of an external device

Abstract

dc:description

The overall aim of this work was to evaluate a newly developed measurement device, the Rottometer, for measuring knee rotation in different flexion angles with different applied torques, in order to establish the normal range of healthy knee rotation reference values and to study possible differences due to age and gender, as well as possible differences between patients with habitual dislocating patella (HDP) and healthy controls. The validity of the Rottometer was evaluated by simultaneous registrations with roentgen stereometric analysis (RSA) (paper I). The two methods showed high correlations concerning the total knee rotation at 90° and 60° of knee flexion angles with 3, 6 and 9 Nm applied torques. The Rottometer was also concluded to be a reliable measurement device concerning the one-week-apart and within day intra-tester as well as the inter-tester reliability at 90°, 60° and 30° with 6 and 9 Nm as well as the examiner’s apprehension of end-feel (paper II). In total, 120 knee healthy subjects (60 females and 60 males) equally distributed in four different age groups (15-30, 31-45, 46-60 and ≥ 61 years) were examined at 90°, 60° and 30° of knee flexion angles with 6 and 9 Nm applied torques as well as the examiner’s apprehension of end-feel (paper III). No differences were found concerning the different flexion angles, between the left and right knee or between the different age groups within the genders. However, the females showed a 10-20 % larger range of knee rotation than the males at all different flexion angles and applied torques. The knee rotation was also examined in 20 patients (15 females and 5 males) with HDP (paper IV). No differences were found between the affected and unaffected knees within the subjects. In accordance with the healthy reference population, the female subjects showed a 10-20 % significantly larger range of rotation than the male subjects in the HDP group, and no differences were found between the patients affected with HDP and age matched healthy controls.

Degree

thesis:*
Grantor dc:publisher
Department of Health Sciences, Lund University
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Almquist, Per Otto

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
urn:isbn:978-91-87189-17-3
OAI identifier oai:identifier
oai:lup.lub.lu.se:8f05547d-ebd4-414a-9661-77bb5b82f688

Chain of custody

source
Harvested from
University of Lund
Base URL
lup.lub.lu.se/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Almquist, Per Otto. Measurements of knee rotation in vivo - Development and evaluation of an external device. Department of Health Sciences, Lund University, 2012. https://lup.lub.lu.se/record/3127987