Physics and Astronomy
Testing of GdCl3 Doping in Water Cherenkov Antineutrino Detectors
Abstract
dc:description.abstractImproved neutron and neutrino detection using water Cherenkov detectors loaded with gadolinium has been proposed for potential application in both large and small volume detectors. In this thesis, work performed to determine the effect on transparency resulting from use of GdCl3 in stainless steel constructed water Cherenkov detectors is presented. In addition, results of an experiment performed using a small volume water Cherenkov de- tector are reported. This was the first use of gadolinium loaded water to detect reactor antineutrinos.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy (PhD)
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Physical Sciences and Mathematics
- Grantor
- Physics and Astronomy
- Year dc:date.available
- 2009
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Coleman, William Fitzgerald
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- unrestricted
- Release the entire work immediately for access worldwide.
Identifiers
dc:identifier.*- Identifier
-
etd-11092009-120419
https://repository.lsu.edu/gradschool_dissertations/84 - OAI identifier oai:identifier
- oai:repository.lsu.edu:gradschool_dissertations-1083