Back to results

Loma Linda University

Correlation of Tooth Length Measurements made on CBCT and 3T MR Images

Abstract

dc:description.abstract

<p>Objective. This study compared tooth length measurements made on cone beam computed tomography (CBCT) scans and 3-Tesla (3T) magnetic resonance (MR) scans performed with and without an alginate bite registration surrounding the crowns of the teeth. Materials and Methods. One CBCT scan, one MR scan with alginate bite registration, and one MR scan without bite registration were performed on 12 subjects. The alginate bite registration was used to provide a proton-rich material to surround proton-poor teeth in an attempt to improve visualization of teeth. DICOM formatted images from each of the three scans for each subject were oriented in all three planes of space. Slices of 4 mm thickness were made through all permanent teeth. Tooth length measurements were made from the slices. Results. The presence of alginate bite registration during MR scans made it impossible to determine tooth lengths on MR images. Tooth lengths measured from CBCT and MR scans without alginate bite registration were very highly correlated. For 336 measurements (N = 336) the correlation coefficient was found to be 0.953 (p < 0.001). Conclusions. 1.) Alginate is not a useful material in increasing visualization of teeth on MR scans. 2.) Tooth length measurements made on MR scans are highly correlated with tooth length measurements made on CBCT scans.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Orthodontics and Dentofacial Orthopedics
Year
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Taylor, Andrew Scott
Contributors dc:contributor
  • Leggitt, V. Leroy
  • Farrage, James
  • Rynearson, R. David

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • This title appears here courtesy of the author, who has granted Loma Linda University a limited, non-exclusive right to make this publication available to the public. The author retains all other copyrights.
Language dc:language
English

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarsrepository.llu.edu/etd/412
OAI identifier oai:identifier
oai:scholarsrepository.llu.edu:etd-1408

Chain of custody

source
Harvested from
Loma Linda University
Base URL
scholarsrepository.llu.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Taylor, Andrew Scott. Correlation of Tooth Length Measurements made on CBCT and 3T MR Images. Thesis thesis, 2016. https://scholarsrepository.llu.edu/etd/412