Loma Linda University
Comparison of Retention between Milled and Conventional Denture Bases: A Clinical Study
Abstract
dc:description.abstract<p>The advancement in dental material technology led to the improvement in the fabrication method of PMMA denture bases. Denture base adaptation can be influenced by the amount of polymerization shrinkage that occurs during the processing method of fabrication. CAD/CAM dentures milled from prepolymerized PMMA acrylic resin blocks theoretically have reduced or no polymerization shrinkage. There have been no clinical studies, to date, that have compared retention values between milled and conventionally processed denture bases. Therefore, the purpose of this study clinical study was to compare the retention values between conventional heat polymerized and digital milled maxillary denture bases.</p> <p>Twenty patients (n=20) with completely edentulous maxillary arches participated in this study. At the first visit, a preliminary impression was made and poured in type III dental stone. A custom tray was constructed from Triad light cure material. At the second visit a heavy body PVS impression material was used to border mold the trays and a final impression was made with light body PVS impression material. The final impression was scanned and the STL files were sent to Global Dental Science for the fabrication of a CAD/CAM milled denture base (AvaDent) (group A). Then the final PVS impression was poured in type III dental stone. The master cast was used to fabricate a heat polymerized acrylic denture base resin (group B). A unique testing device was used to measure denture retention in lbs. The testing device was composed of three parts; DAFG (attached to a motorized test stand), customized FTD and a Panadent earbow ( modified and mounted to a customized wooden stand). The FTD consisted of a hollow brass rod with a pulley at each end used to transfer the force through a nylon thread. A snap hook attachment was attached to the denture base at the center with autopolymerizing resin. The nylon thread was tied securely to the snap hook. At the other end the nylon thread was attached to the DAFG through a secure grip attachment. Each denture base was subjected to a vertical pulling force three times at 10-minute intervals.</p> <p>The statistical analysis showed significant (α>.05) increase in retention for milled denture base method of fabrication over the conventional polymerizing method with a mean (N) difference of 4.47 lbs (<em>P</em><0.001). Average retention for the milled denture bases was 16.66 ± 7.32 lbs and average retention for the conventional heat polymerized denture bases was 12.19 ± 6.15 lbs.</p> <p>Based on analysis of results, it was concluded that the retention of digitally designed and milled complete denture bases from prepolymerized PMMA acrylic resin blocks offer significantly higher retention than the denture bases fabricated by a conventional heat polymerized method.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MS)
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Prosthodontics
- Year
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- AlHelal, Abdulaziz Abdullah
- Contributors dc:contributor
-
- Kattadiyil, Mathew T.
- Baba, Nadim Z.
- Goodacre, Charles J.
Subjects
dc:subject × 5Rights
dc:rights- Statement dc:rights
-
- This title appears here courtesy of the author, who has granted Loma Linda University a limited, non-exclusive right to make this publication available to the public. The author retains all other copyrights.
- Language dc:language
- English
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://scholarsrepository.llu.edu/etd/323
- OAI identifier oai:identifier
- oai:scholarsrepository.llu.edu:etd-1316