{"id":{"repo_id":"loma-linda","oai_identifier":"oai:scholarsrepository.llu.edu:etd-1105"},"canonical_url":"https://search.dev.ndltd.org/etd/loma-linda/oai:scholarsrepository.llu.edu:etd-1105","repository":{"repo_id":"loma-linda","name":"Loma Linda University","base_url":"https://scholarsrepository.llu.edu/do/oai/"},"display":{"title":"Effect of Time on Gypsum-Impression Material Compatibility","abstract":"The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were AlginotÂ® (Kerrâ„¢), Position Penta QuickÂ® (3M ESPEâ„¢) and SilgimixÂ® (Sultan Dentalâ„¢). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobialÂ® (Dentsply Caulkâ„¢) served as the control. Materials and Methods: Testing of materials was conducted in accordance with ANSI/ADA Specification No. 18 for Alginate Impression Materials. Statistical Analysis: The 3-Way ANOVA test was used to analyze measurements between different time points at a significance level of (p &lt; 0.05) Outcome: It was found that there was greater compatibility between gypsum and the alternative materials over time than the traditional irreversible hydrocolloid material that was tested. A statistically significant amount of surface change/incompatibility was found over time with the combination of the dental gypsum products and the control impression material (Jeltrate Plus antimicrobialÂ®).","abstract_html":"The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were AlginotÂ® (Kerrâ„¢), Position Penta QuickÂ® (3M ESPEâ„¢) and SilgimixÂ® (Sultan Dentalâ„¢). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobialÂ® (Dentsply Caulkâ„¢) served as the control. Materials and Methods: Testing of materials was conducted in accordance with ANSI/ADA Specification No. 18 for Alginate Impression Materials. Statistical Analysis: The 3-Way ANOVA test was used to analyze measurements between different time points at a significance level of (p &amp;lt; 0.05) Outcome: It was found that there was greater compatibility between gypsum and the alternative materials over time than the traditional irreversible hydrocolloid material that was tested. A statistically significant amount of surface change/incompatibility was found over time with the combination of the dental gypsum products and the control impression material (Jeltrate Plus antimicrobialÂ®).","abstract_has_math":false,"creators":["Won, John Boram"],"institution":null,"degree_name":"Master of Science (MS)","degree_level":"Thesis","degree_discipline":"Prosthodontics","degree_department":null,"school":null,"contributors":["Kattadiyil, Mathew","Goodacre, Charles","Lozada, Jaime","Winer, Myron"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-08-01T07:00:00Z","date_published":"2012-08-01T07:00:00Z","updated_at":"2026-07-24T02:52:15Z","subjects":["Prosthodontics and Prosthodontology","Dental impression technique; Dental impression materials;","Gypsum Impression Material","Dental gypsum","Irreversible hydrocolloid material","Prosthodontics"],"languages":["English"],"rights":["This title appears here courtesy of the author, who has granted Loma Linda University a limited, non-exclusive right to make this publication available to the public. The author retains all other copyrights."],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://scholarsrepository.llu.edu/etd/106","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kattadiyil, Mathew","Goodacre, Charles","Lozada, Jaime","Winer, Myron"]},{"key":"dc:creator","label":"Author","values":["Won, John Boram"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"thesis:degree_discipline","label":"Discipline","values":["Prosthodontics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Prosthodontics and Prosthodontology","Dental impression technique; Dental impression materials;","Gypsum Impression Material","Dental gypsum","Irreversible hydrocolloid material","Prosthodontics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["This title appears here courtesy of the author, who has granted Loma Linda University a limited, non-exclusive right to make this publication available to the public. The author retains all other copyrights."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsrepository.llu.edu/etd/106"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were AlginotÂ® (Kerrâ„¢), Position Penta QuickÂ® (3M ESPEâ„¢) and SilgimixÂ® (Sultan Dentalâ„¢). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobialÂ® (Dentsply Caulkâ„¢) served as the control. Materials and Methods: Testing of materials was conducted in accordance with ANSI/ADA Specification No. 18 for Alginate Impression Materials. Statistical Analysis: The 3-Way ANOVA test was used to analyze measurements between different time points at a significance level of (p &lt; 0.05) Outcome: It was found that there was greater compatibility between gypsum and the alternative materials over time than the traditional irreversible hydrocolloid material that was tested. A statistically significant amount of surface change/incompatibility was found over time with the combination of the dental gypsum products and the control impression material (Jeltrate Plus antimicrobialÂ®)."]},{"key":"dc:title","label":"Title","values":["Effect of Time on Gypsum-Impression Material Compatibility"]}]}],"canonical_facts":{"dc:contributor":["Kattadiyil, Mathew","Goodacre, Charles","Lozada, Jaime","Winer, Myron"],"dc:creator":["Won, John Boram"],"dc:description.abstract":["The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were AlginotÂ® (Kerrâ„¢), Position Penta QuickÂ® (3M ESPEâ„¢) and SilgimixÂ® (Sultan Dentalâ„¢). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobialÂ® (Dentsply Caulkâ„¢) served as the control. Materials and Methods: Testing of materials was conducted in accordance with ANSI/ADA Specification No. 18 for Alginate Impression Materials. Statistical Analysis: The 3-Way ANOVA test was used to analyze measurements between different time points at a significance level of (p &lt; 0.05) Outcome: It was found that there was greater compatibility between gypsum and the alternative materials over time than the traditional irreversible hydrocolloid material that was tested. A statistically significant amount of surface change/incompatibility was found over time with the combination of the dental gypsum products and the control impression material (Jeltrate Plus antimicrobialÂ®)."],"dc:identifier":["https://scholarsrepository.llu.edu/etd/106"],"dc:language":["English"],"dc:rights":["This title appears here courtesy of the author, who has granted Loma Linda University a limited, non-exclusive right to make this publication available to the public. The author retains all other copyrights."],"dc:subject":["Prosthodontics and Prosthodontology","Dental impression technique; Dental impression materials;","Gypsum Impression Material","Dental gypsum","Irreversible hydrocolloid material","Prosthodontics"],"dc:title":["Effect of Time on Gypsum-Impression Material Compatibility"],"thesis:degree_discipline":["Prosthodontics"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science (MS)"]},"updated_at":"2026-07-24T02:52:15Z"}