{"id":{"repo_id":"lethbridge","oai_identifier":"oai:opus.uleth.ca:10133/6671"},"canonical_url":"https://search.dev.ndltd.org/etd/lethbridge/oai:opus.uleth.ca:10133/6671","repository":{"repo_id":"lethbridge","name":"University of Lethbridge","base_url":"https://opus.uleth.ca/server/oai/request"},"display":{"title":"A cryogenic multiaxis range-resolved laser interferometer","abstract":"Building upon the successes of previous far-infrared space astronomy missions that initially featured small but cold (<4 K) or large but warm telescopes, the future path is clear: the next generation of far-infrared telescopes must be both large and cold, which requires cryogenic cooling of the mirrors, instrumentation, and detectors. The precision to which the moving cryogenic components of the instrument must be measured and controlled demands a robust low power position metrology system, and a cryogenic multiaxis range-resolved laser interferometer using a sinusoidal frequency modulation (SFM) technique was investigated to solve this problem. The development included cryogenic considerations and characterization of several fibre and optical components, calibration of the selected hardware, and verification of the technique. Simultaneous multiaxis measurements were demonstrated at ambient and cryogenic temperatures of <6 K, and the measured performance under ambient conditions showed a resolution of ~50 pm and a stability of 0.4 nm rms in a 20 Hz bandwidth. The demonstrated performance exceeds that which is required by proposed far-infrared missions and distinguishes the SFM range-resolved laser interferometer as a leading candidate for future space-based applications.","abstract_html":"Building upon the successes of previous far-infrared space astronomy missions that initially featured small but cold (&lt;4 K) or large but warm telescopes, the future path is clear: the next generation of far-infrared telescopes must be both large and cold, which requires cryogenic cooling of the mirrors, instrumentation, and detectors. The precision to which the moving cryogenic components of the instrument must be measured and controlled demands a robust low power position metrology system, and a cryogenic multiaxis range-resolved laser interferometer using a sinusoidal frequency modulation (SFM) technique was investigated to solve this problem. The development included cryogenic considerations and characterization of several fibre and optical components, calibration of the selected hardware, and verification of the technique. Simultaneous multiaxis measurements were demonstrated at ambient and cryogenic temperatures of &lt;6 K, and the measured performance under ambient conditions showed a resolution of ~50 pm and a stability of 0.4 nm rms in a 20 Hz bandwidth. The demonstrated performance exceeds that which is required by proposed far-infrared missions and distinguishes the SFM range-resolved laser interferometer as a leading candidate for future space-based applications.","abstract_has_math":false,"creators":["Christiansen, Adam J.","University of Lethbridge. Faculty of Arts and Science"],"institution":"Lethbridge, Alta. : University of Lethbridge, Dept. of Physics and Astronomy","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Naylor, David A."],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-08-21T16:45:58Z","subjects":["Laser","Metrology","Range-resolved","Interferometry","Cryogenic","Optics","Photonics","Fiber","Fiber optics","Astronomy","Astrophysics","Multiaxis","Multiplexing","FPGA","Signal processing","DSP","Ranging","Displacement","Frequency modulation","Embedded systems","Far-infrared"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:10133/6671"],"render_values":[{"text":"hdl:10133/6671","href":null,"code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/10133/6671","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"source_record":{"url":"https://opus.uleth.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopus.uleth.ca%3A10133%2F6671","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Naylor, David A."]},{"key":"dc:creator","label":"Author","values":["Christiansen, Adam J.","University of Lethbridge. Faculty of Arts and Science"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-01-25T21:03:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-01-25T21:03:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Lethbridge, Alta. : University of Lethbridge, Dept. of Physics and Astronomy"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Physics and Astronomy"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Laser","Metrology","Range-resolved","Interferometry","Cryogenic","Optics","Photonics","Fiber","Fiber optics","Astronomy","Astrophysics","Multiaxis","Multiplexing","FPGA","Signal processing","DSP","Ranging","Displacement","Frequency modulation","Embedded systems","Far-infrared"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["hdl:10133/6671"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10133/6671"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Building upon the successes of previous far-infrared space astronomy missions that initially featured small but cold (<4 K) or large but warm telescopes, the future path is clear: the next generation of far-infrared telescopes must be both large and cold, which requires cryogenic cooling of the mirrors, instrumentation, and detectors. The precision to which the moving cryogenic components of the instrument must be measured and controlled demands a robust low power position metrology system, and a cryogenic multiaxis range-resolved laser interferometer using a sinusoidal frequency modulation (SFM) technique was investigated to solve this problem. The development included cryogenic considerations and characterization of several fibre and optical components, calibration of the selected hardware, and verification of the technique. Simultaneous multiaxis measurements were demonstrated at ambient and cryogenic temperatures of <6 K, and the measured performance under ambient conditions showed a resolution of ~50 pm and a stability of 0.4 nm rms in a 20 Hz bandwidth. The demonstrated performance exceeds that which is required by proposed far-infrared missions and distinguishes the SFM range-resolved laser interferometer as a leading candidate for future space-based applications."]},{"key":"dc:description.other","label":"Dc Description Other","values":["Building upon the successes of previous far-infrared space astronomy missions that initially featured small but cold (<4 K) or large but warm telescopes, the future path is clear: the next generation of far-infrared telescopes must be both large and cold, which requires cryogenic cooling of the mirrors, instrumentation, and detectors. The precision to which the moving cryogenic components of the instrument must be measured and controlled demands a robust low power position metrology system, and a cryogenic multiaxis range-resolved laser interferometer using a sinusoidal frequency modulation (SFM) technique was investigated to solve this problem. The development included cryogenic considerations and characterization of several fibre and optical components, calibration of the selected hardware, and verification of the technique. Simultaneous multiaxis measurements were demonstrated at ambient and cryogenic temperatures of <6 K, and the measured performance under ambient conditions showed a resolution of ~50 pm and a stability of 0.4 nm rms in a 20 Hz bandwidth. The demonstrated performance exceeds that which is required by proposed far-infrared missions and distinguishes the SFM range-resolved laser interferometer as a leading candidate for future space-based applications."]},{"key":"dc:title","label":"Title","values":["A cryogenic multiaxis range-resolved laser interferometer"]}]}],"canonical_facts":{"dc:contributor.supervisor":["Naylor, David A."],"dc:creator":["Christiansen, Adam J.","University of Lethbridge. Faculty of Arts and Science"],"dc:date.accessioned":["2024-01-25T21:03:15Z"],"dc:date.available":["2024-01-25T21:03:15Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Building upon the successes of previous far-infrared space astronomy missions that initially featured small but cold (<4 K) or large but warm telescopes, the future path is clear: the next generation of far-infrared telescopes must be both large and cold, which requires cryogenic cooling of the mirrors, instrumentation, and detectors. The precision to which the moving cryogenic components of the instrument must be measured and controlled demands a robust low power position metrology system, and a cryogenic multiaxis range-resolved laser interferometer using a sinusoidal frequency modulation (SFM) technique was investigated to solve this problem. The development included cryogenic considerations and characterization of several fibre and optical components, calibration of the selected hardware, and verification of the technique. Simultaneous multiaxis measurements were demonstrated at ambient and cryogenic temperatures of <6 K, and the measured performance under ambient conditions showed a resolution of ~50 pm and a stability of 0.4 nm rms in a 20 Hz bandwidth. The demonstrated performance exceeds that which is required by proposed far-infrared missions and distinguishes the SFM range-resolved laser interferometer as a leading candidate for future space-based applications."],"dc:description.other":["Building upon the successes of previous far-infrared space astronomy missions that initially featured small but cold (<4 K) or large but warm telescopes, the future path is clear: the next generation of far-infrared telescopes must be both large and cold, which requires cryogenic cooling of the mirrors, instrumentation, and detectors. The precision to which the moving cryogenic components of the instrument must be measured and controlled demands a robust low power position metrology system, and a cryogenic multiaxis range-resolved laser interferometer using a sinusoidal frequency modulation (SFM) technique was investigated to solve this problem. The development included cryogenic considerations and characterization of several fibre and optical components, calibration of the selected hardware, and verification of the technique. Simultaneous multiaxis measurements were demonstrated at ambient and cryogenic temperatures of <6 K, and the measured performance under ambient conditions showed a resolution of ~50 pm and a stability of 0.4 nm rms in a 20 Hz bandwidth. The demonstrated performance exceeds that which is required by proposed far-infrared missions and distinguishes the SFM range-resolved laser interferometer as a leading candidate for future space-based applications."],"dc:identifier":["hdl:10133/6671"],"dc:identifier.uri":["https://hdl.handle.net/10133/6671"],"dc:language.iso":["en"],"dc:publisher":["Lethbridge, Alta. : University of Lethbridge, Dept. of Physics and Astronomy"],"dc:publisher.department":["Department of Physics and Astronomy"],"dc:subject":["Laser","Metrology","Range-resolved","Interferometry","Cryogenic","Optics","Photonics","Fiber","Fiber optics","Astronomy","Astrophysics","Multiaxis","Multiplexing","FPGA","Signal processing","DSP","Ranging","Displacement","Frequency modulation","Embedded systems","Far-infrared"],"dc:title":["A cryogenic multiaxis range-resolved laser interferometer"],"dc:type":["Thesis"]},"updated_at":"2026-08-21T16:45:58Z"}