Back to results

University of Kansas

Development of Dual-Electrode Amperometric Detectors for Liquid Chromatography and Capillary Electrophoresis

Abstract

dc:description.abstract

Abstract The body of this research was focused on the use and development dual-electrode detection schemes for liquid chromatography and capillary electrophoresis. These detection schemes were developed to investigate redox chemistries for endogenous and exogenous antioxidants that play key roles in maintaining tissue redox homeostasis under oxidative stress conditions. A parallel adjacent dual electrode detector was first proposed for liquid chromatography in which redox cycling was hypothesized to occur between the electrodes resulting in signal enhancement. Flow rates for these systems were too high (≥ 1.0 mL) to obtain redox cycling and subsequently no signal enhancement was observed for these systems. Flow rates in capillary electrophoresis are significantly lower compared to liquid chromatography. Therefore, a parallel dual–electrode was developed for capillary electrophoresis in this work. The dual–electrode was investigated using reduced phenolic acids, which were chemically reversible, semi–reversible and non-reversible compounds allowing all potential electrochemistry’s to be investigated. Redox cycling and signal enhancement was observed with the developed dual–electrode. Furthermore, the parallel dual–electrode could be operated in either a redox cycling mode or dual–potential mode, where either chemical reversibility or voltammetry could be used as a means to confirm migration based peak identification, respectively. The same design was then applied for a dual Au/Hg electrode for capillary electrophoresis, in which thiols and disulfides were investigated in vivo. With the developed dual Au/Hg electrode redox changes were observed as a result of chemically induced oxidative stress.

Degree

thesis:*
Grantor dc:publisher
University of Kansas
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Dorris, Megan
Advisor dc:contributor.advisor
  • Lunte, Craig E.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • This item is protected by copyright and unless otherwise specified the copyright of this thesis/dissertation is held by the author.
Language dc:language.iso
en

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:kuscholarworks.ku.edu:1808/12291

Chain of custody

source
Harvested from
University of Kansas
Base URL
kuscholarworks.ku.edu/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Dorris, Megan. Development of Dual-Electrode Amperometric Detectors for Liquid Chromatography and Capillary Electrophoresis. University of Kansas, 2013. http://hdl.handle.net/1808/12291