Back to results

University of Houston

Use of Motion Artifact for the Detection of Respiratory Effort in Polysomnography

Abstract

dc:description.abstract

Measuring respiratory effort is critical when diagnosing sleep disordered breathing. In this thesis work, the use of detecting respiratory effort by using the movement artifact found in the electromyographic (EMG) and electrocardiographic (ECG) recordings used in polysomnography was investigated. The resulting signals were compared to effort measured with respiratory inductance plethysmography (RIP). The EMG and ECG signals were filtered using the Savitzy-Golay method of smoothing and differentiation of data by simplified least squares to extract the movement artifact. The validity of each resultant waveform was measured using a Pearson product moment correlation coefficient and were studied to determine the most reliable signal. A total of 12 subjects were recorded in a clinical setting, all being evaluated for obstructive sleep apnea. The ability to detect respiratory effort using movement artifact was found to perform best in the masseter. This work shows that movement artifact recovered from the EMG and ECG may be a reliable alternative for the detection of respiratory effort.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Biomedical Engineering
Level thesis:degree_level
Masters
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
University of Houston
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tekchandani, Jatin Murlidhar
Advisor dc:contributor.advisor
  • Zhang, Yingchun
Committee members dc:contributor.committeemember
  • Tiu, Alexander
  • Ince, Nuri F.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • The author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10657/7872
OAI identifier oai:identifier
oai:uh-ir.tdl.org:10657/7872

Chain of custody

source
Harvested from
University of Houston
Base URL
uh-ir.tdl.org/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Tekchandani, Jatin Murlidhar. Use of Motion Artifact for the Detection of Respiratory Effort in Polysomnography. Masters thesis, University of Houston, 2018. https://hdl.handle.net/10657/7872