Back to results

University of Houston

Effective Methods To Reduce The RF-Induced Heating For Medical Implants In MRI

Abstract

dc:description.abstract

Radiofrequency (RF) –induced heating is one of the primary safety concerns for patients with medical implants undergoing magnetic resonance imaging (MRI). Due to this potential hazard, patients with medical devices are usually contraindicated from the MRI process. With the steady growth in the number of patients with medical implants that require MRI, it is important to address the issue of RF heating in MRI. This dissertation focuses on techniques and methods to reduce the RF-induced heating so that patients with medical implants can undergo MRI safely. For the implantable leads, it was proposed to modify the electrode structure to reduce the RF-induced heating. We show that enlarging the electrode contact reduces the rate of RF energy deposition at the electrode, which results in less RF-induced heating at the lead tip. For the external fixation devices, the strategy of using capacitive structures has been investigated to reduce the RF-induced heating. Both simulations and experiments demonstrated that introducing proper capacitive structures to the external fixation device could reduce the temperature rise by more than 95% at both 1.5 T and 3 T. An equivalent circuit was developed to illustrate the heating reduction effect of the capacitive structures in the external fixation device. It is concluded from the circuit model that increasing the equivalent impedance of the external fixation device reduces the RF-induced heating. For the passive implants, we investigated the effects of two different incident RF fields generated by a transverse electromagnetic (TEM) coil and a birdcage (BC) coil on the RF-induced heating. Electromagnetic simulation results show that the BC coil generates a stronger incident electric field along the coil bore than the TEM coil does. Due to this reason, orthopedic plates and spinal fixations caused a higher RF heating in the BC coil than they did in the TEM coil. For passive implants with large dimensions along the coil bore, the TEM coil provides a greater safety margin for patients while the BC coil provides a more conservative heating evaluation.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Grantor
University of Houston
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yang, Rui
Advisor dc:contributor.advisor
  • Chen, Ji
Committee members dc:contributor.committeemember
  • Jackson, David R.
  • Chen, Jiefu
  • Benhaddou, Driss
  • Kainz, Wolfgang

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • The author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. UH Libraries has secured permission to reproduce any and all previously published materials contained in the work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10657/6740
OAI identifier oai:identifier
oai:uh-ir.tdl.org:10657/6740

Chain of custody

source
Harvested from
University of Houston
Base URL
uh-ir.tdl.org/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Yang, Rui. Effective Methods To Reduce The RF-Induced Heating For Medical Implants In MRI. Doctoral thesis, University of Houston, 2020. https://hdl.handle.net/10657/6740