Effective Methods To Reduce The RF-Induced Heating For Medical Implants In MRI
Abstract
dc:description.abstractRadiofrequency (RF) –induced heating is one of the primary safety concerns for patients with medical implants undergoing magnetic resonance imaging (MRI). Due to this potential hazard, patients with medical devices are usually contraindicated from the MRI process. With the steady growth in the number of patients with medical implants that require MRI, it is important to address the issue of RF heating in MRI. This dissertation focuses on techniques and methods to reduce the RF-induced heating so that patients with medical implants can undergo MRI safely. For the implantable leads, it was proposed to modify the electrode structure to reduce the RF-induced heating. We show that enlarging the electrode contact reduces the rate of RF energy deposition at the electrode, which results in less RF-induced heating at the lead tip. For the external fixation devices, the strategy of using capacitive structures has been investigated to reduce the RF-induced heating. Both simulations and experiments demonstrated that introducing proper capacitive structures to the external fixation device could reduce the temperature rise by more than 95% at both 1.5 T and 3 T. An equivalent circuit was developed to illustrate the heating reduction effect of the capacitive structures in the external fixation device. It is concluded from the circuit model that increasing the equivalent impedance of the external fixation device reduces the RF-induced heating. For the passive implants, we investigated the effects of two different incident RF fields generated by a transverse electromagnetic (TEM) coil and a birdcage (BC) coil on the RF-induced heating. Electromagnetic simulation results show that the BC coil generates a stronger incident electric field along the coil bore than the TEM coil does. Due to this reason, orthopedic plates and spinal fixations caused a higher RF heating in the BC coil than they did in the TEM coil. For passive implants with large dimensions along the coil bore, the TEM coil provides a greater safety margin for patients while the BC coil provides a more conservative heating evaluation.
Degree
thesis:*- Name thesis:degree_name
- Doctor of Philosophy
- Level thesis:degree_level
- Doctoral
- Discipline thesis:degree_discipline
- Electrical Engineering
- Grantor
- University of Houston
- Year dc:date.issued
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Yang, Rui
- Advisor dc:contributor.advisor
-
- Chen, Ji
- Committee members dc:contributor.committeemember
-
- Jackson, David R.
- Chen, Jiefu
- Benhaddou, Driss
- Kainz, Wolfgang
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- The author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. UH Libraries has secured permission to reproduce any and all previously published materials contained in the work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
- Language dc:language.iso
- eng
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10657/6740
- OAI identifier oai:identifier
- oai:uh-ir.tdl.org:10657/6740