Back to results

University of Houston

Non-Contact Lap Splices in Geometrically Dissimilar Bridge Column to Drilled Shaft Connections

Abstract

dc:description.abstract

Contact lap splices are widely used for the construction of reinforced concrete structures. But, it is often required to provide a reinforcing steel splicing arrangement with non-contact lap splices due to the limitation of internal space or geometric irregularity for the connection of non-circular bridge columns interfacing directly with circular drilled shafts. However, there is a concern on the safety and cost-effectiveness of such non-contact lap splices because the guidelines in the current AASHTO LRFD code and studies on this type of connection are limited. This study presents an experimental and analytical investigation of non-contact lap splices in non-circular bridge column to circular drilled shaft connections. Eleven large-scale column-drilled shaft specimens were tested to investigate the effects of the critical parameters affecting the performance of non-contact lap splices: the non-contact distance between the spliced bars, the lap splice length and the amount of transverse reinforcement in the non-contact lap splice zone. The specimens were subjected to flexure action with both monotonic and cyclic loading. The test results showed that the specimens with larger non-contact splice distance generally exhibited lower lateral stiffness and lower capacity. The increase in the non-contact splice distance yielded significant inclined cracks and splitting cracks in the non-contact lap splice zone. The angle of inclined cracks was observed to increase with increasing the non-contact splice distance. Furthermore, a three-dimensional finite element analysis (FEA) was performed on the test specimens, and the finite element simulated results were compared with the test outcomes. Using the validated FEA models, a thorough parametric study was performed to understand the effect of the critical parameters. The results of this study provide a basic understanding of the behavior of non-contact lap splices in non-circular columns to circular drilled shaft connections. Based on the findings from the experimental and analytical investigation, a set of design recommendations is provided for the design of non-contact splices in geometrically dissimilar bridge column to drilled shaft connections. In conclusion, with the consideration of the current AASHTO LRFD code and the proposed guidelines, a safe and efficient non-circular column to circular drilled shaft connection can be constructed.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Civil Engineering
Grantor
University of Houston
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Masud, Mahadi
Advisor dc:contributor.advisor
  • Mo, Yi-Lung
Committee members dc:contributor.committeemember
  • Hsu, Thomas T. C.
  • Lin, Yongqian
  • Mansour, Mohamad Y.
  • Laskar, Arghadeep

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • The author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. UH Libraries has secured permission to reproduce any and all previously published materials contained in the work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10657/5788
OAI identifier oai:identifier
oai:uh-ir.tdl.org:10657/5788

Chain of custody

source
Harvested from
University of Houston
Base URL
uh-ir.tdl.org/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Masud, Mahadi. Non-Contact Lap Splices in Geometrically Dissimilar Bridge Column to Drilled Shaft Connections. Doctoral thesis, University of Houston, 2019. https://hdl.handle.net/10657/5788