Back to results

University of Houston

Numerical and Experimental Study of Pacemaker Safety under MRI

Abstract

dc:description.abstract

Pacemaker safety issues with MRI (Magnetic Resonance Imaging) are discussed in this thesis. In order to analyze the electromagnetic compatibility issue of pacemaker/defibrillator with MRI RF (radio frequency) coil and human body model, novel techniques for the evaluation of MRI-induced heating or induced voltage in the vicinity of implanted metallic lead have been developed based on the reciprocity theorem. The measurement configurations have been described in detail. The technique was validated in both numerical and experimental studies on different lead structures. More than one hundred transfer functions of real practical pacemakers are measured, and hundreds of validation tests were performed on those transfer functions. In addition, the effects of human body/phantom were also discussed based on the measured transfer functions and human body simulations. This approach allows one to decouple the micro-scale metallic lead simulation/measurement from the macro-level phantom human simulations within the MRI scanners. Consequently, the estimation of MRI-induced heating on an implanted lead, and the induced voltage on the pacemaker device can be greatly simplified. The analysis about the pacemaker safety issue will become very efficient. In addition, this method clearly explains the induced lead heating mechanism during MRI procedures.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Grantor
University of Houston
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Feng, Shi
Advisor dc:contributor.advisor
  • Chen, Ji
Committee members dc:contributor.committeemember
  • Jackson, David R.
  • Wilton, Donald R.
  • Zouridakis, George
  • Kainz, Wolfgang

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • The author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10657/2806
OAI identifier oai:identifier
oai:uh-ir.tdl.org:10657/2806

Chain of custody

source
Harvested from
University of Houston
Base URL
uh-ir.tdl.org/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Feng, Shi. Numerical and Experimental Study of Pacemaker Safety under MRI. Doctoral thesis, University of Houston, 2014. http://hdl.handle.net/10657/2806