Back to results

University of Houston

MRI Safety Evaluation of Dual Leads and Fractured Leads Active Implantable Medical Devices in MRI

Abstract

dc:description.abstract

Magnetic resonance imaging (MRI) radiofrequency (RF)-induced heating is of great concern for patients with active implantable medical devices (AIMDs) undergo MR scanning. RF safety evaluation of AIMDs consists of two steps: (1) the development of the AIMD model (i.e., transfer function (TF) method), and (2) the extraction of the incident E-field along clinically relevant pathways inside human body models. In this dissertation, we first evaluate RF-induced heating of AIMD systems with dual leads using simulations and experiments. Coupling effects, which lead to lower RF-induced SAR or heating, between dual leads are observed in both simulations and experiments. Results show that separation distance of two leads can affect strength of coupling effects. By introducing global TF, in-vivo heating estimations are performed. The findings reveal that dual leads configurations will have lower RF-induced heating compared to that of single lead configuration. Secondly, RF-induced heating of AIMDs with fractured leads and abandoned lead fragments are discussed. Experiments in combination with in-vivo simulations show that AIMDs with fractured lead will induce excessive RF heating and abandoned lead fragments are MRI safe. Third part of the dissertation discusses MR conditionality of abandoned fractured leads. Two proximal treatments (bare-end, capped-end) are compared. Two important observations are summarized: (1) abandoned fractured leads will have unpredictable RF-induced heating (either higher or lower than that of abandoned intact lead), (2) bare-end treatment will lead to lower heating than that of capped-end treatment. Finally, a novel technique to reduce RF-induced of heating from AIMD is proposed. By adding magnetic ferrite beads with high permeability to AIMD systems, Transfer Function (TF) magnitude can be suppressed significantly for both 1.5 T and 3 T. In-vivo results of AIMDs with different magnetic ferrite beads configurations (1 or 2 ferrite beads or 1 bead with two different locations) are studied and indicate that magnetic ferrite beads can reduce RF-induced heating.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Grantor
University of Houston
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hu, Wei
Advisor dc:contributor.advisor
  • Chen, Ji
Committee members dc:contributor.committeemember
  • Jackson, David R.
  • Chen, Jiefu
  • Kainz, Wolfgang
  • Benhaddou, Driss

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • The author of this work is the copyright owner. UH Libraries and the Texas Digital Library have their permission to store and provide access to this work. UH Libraries has secured permission to reproduce any and all previously published materials contained in the work. Further transmission, reproduction, or presentation of this work is prohibited except with permission of the author(s).
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10657/13337
OAI identifier oai:identifier
oai:uh-ir.tdl.org:10657/13337

Chain of custody

source
Harvested from
University of Houston
Base URL
uh-ir.tdl.org/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Hu, Wei. MRI Safety Evaluation of Dual Leads and Fractured Leads Active Implantable Medical Devices in MRI. Doctoral thesis, University of Houston, 2022. https://hdl.handle.net/10657/13337