Back to results

Universität Heidelberg

Development and Optimisation of Radial Techniques for Sodium Magnetic Resonance Imaging

Abstract

dc:description.abstract

The goal of this work was to provide techniques and hardware for 23Na MRI of the human brain, heart and muscle in a clinical scanner at 1.5T. For this purpose, radiofrequency (RF) coils were developed and a transmit/receive switch was adapted to 16.84 MHz. A 3D radial gradient echo (GRE) sequence was implemented, with a minimum echo time TEmin = 0.07ms for 1H and 0.2ms for 23Na, allowing to detect both the short (T2= 0.5ms) and the long (T2= 12-25ms) components of the 23Na NMR signal for total 23Na content evaluation. A gridding reconstruction algorithm with a Kaiser-Bessel window and a rho filter was implemented and optimised for both 23Na and 1H MRI. At an acquisition time Tacq= 10min and a nominal resolution Dx= 4mm, the signal-to-noise ratio SNR of the in-vivo 23Na 3D radial images was twofold higher than in standard cartesian GRE MRI (TEmin= 2ms). In the radial images blurring due to T2 signal decay during data acquisition was observed, reducing the resolution by approximately a factor of two. Both cartesian and radial GRE methods were compared at 1.5T and 4T. An SNR increase of SNR(4T)/SNR(1.5T) ~4 was measured in-vivo. In brain tumour patients, a 20% 23Na MRI signal increase in the tumour region was detected. A contrast-to-noise ratio CNR = 23% between healthy tissue and tumour achieved with the 3D radial was 20% higher than the CNR of the cartesian sequence. In patients with a 23Na channel disfunction, a 23Na MRI signal increase of ~10% was measured. This method allows for the detection of changes in the intracellular 23Na concentration and may provide a new tool to non-invasively evaluate tissue vitality.

Degree

thesis:*
Level thesis:degree_level
thesis.doctoral
Grantor dc:publisher
Universität Heidelberg
Year
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nielles-Vallespin, Sonia
Contributors dc:contributor
  • Schad, Lothar R.

Identifiers

dc:identifier.*
Repository record source_url
http://www.ub.uni-heidelberg.de/archiv/5262
OAI identifier oai:identifier
oai:archiv.ub.uni-heidelberg.de:5262

Chain of custody

source
Harvested from
Universität Heidelberg
Base URL
archiv.ub.uni-heidelberg.de/volltextserver/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation