Abstract

dc:description.abstract

The research involved a synthesis of national guidelines, interviews with GDOT personnel and industry stakeholders, and full-scale experimental testing of BT-54 girders with simulated nonconformance issues. Results showed that top flange repairs consistently exceeded original girder strength, while bottom flange repairs were generally effective except in bearing zones and transfer regions, where re-tensioning methods failed due to poor strand-concrete bonding. Reinforced repair surfaces demonstrated strong adhesion and structural performance, reaching at least 95% of nominal moment capacity and 90% of nominal shear capacity. Recommendations include simplifying top flange repair procedures, reconsidering the use of epoxy bonding agents, and ensuring adequate exposure of steel reinforcement for proper bond of bottom flange repairs.

Degree

thesis:*
Name thesis:degree_name
Civil Engineering, MS
Grantor
Georgia Institute of Technology
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Contreras, Ana Karina
Advisor dc:contributor.advisor
  • Stewart, Lauren K.
Committee members dc:contributor.committeemember
  • Meyer, Karl
  • Kahn, Lawrence

Rights

Language dc:language.iso
English

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/80278
OAI identifier oai:identifier
oai:repository.gatech.edu:1853/80278

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
related terms
citation

Contreras, Ana Karina. Evaluation of Repairs Conducted on Full-Scale, Non-Conforming/Defective Prestressed Concrete Girders (PCI BT-54). Georgia Institute of Technology, 2025. https://hdl.handle.net/1853/80278