{"id":{"repo_id":"etsu","oai_identifier":"oai:dc.etsu.edu:etd-2338"},"canonical_url":"https://search.dev.ndltd.org/etd/etsu/oai:dc.etsu.edu:etd-2338","repository":{"repo_id":"etsu","name":"East Tennessee State University","base_url":"https://dc.etsu.edu/do/oai/"},"display":{"title":"Study of Immobilizing Cadmium Selenide Quantum Dots in Selected Polymers for Application in Peroxyoxalate Chemiluminescence Flow Injection Analysis","abstract":"<p>Two batches of CdSe QDs with different sizes were synthesized for immobilizing in polyisoprene (PI), polymethylmethacrylate (PMMA), and low-density polyethylene (LDPE). The combinations of QDs and polymer substrates were evaluated for their analytical fit-for-use in applicable immunoassays. Hydrogen peroxide standards were injected into the flow injection analyzer (FIA) constructed to simulate enzyme-generated hydrogen peroxide reacting with bis-(2,4,6-trichlorophenyl) oxalate.</p> <p>Linear correlations between hydrogen peroxide and chemilumenscent intensities yielded regression values greater than 0.9750 for hydrogen peroxide concentrations between 1.0 x 10<sup>-4</sup> M and 1.0 x 10<sup>-1</sup> M. The developed technique’s LOD was approximately 10 ppm. Variability of the prepared QD-polymer products was as low as 3.2% throughout all preparations.Stability of the preparations was tested during a 30-day period that displayed up to a four-fold increase in the first 10 days. The preparations were decently robust to the FIA system demonstrating up to a 15.20% intensity loss after twenty repetitive injections.</p>","abstract_html":"&lt;p&gt;Two batches of CdSe QDs with different sizes were synthesized for immobilizing in polyisoprene (PI), polymethylmethacrylate (PMMA), and low-density polyethylene (LDPE). The combinations of QDs and polymer substrates were evaluated for their analytical fit-for-use in applicable immunoassays. Hydrogen peroxide standards were injected into the flow injection analyzer (FIA) constructed to simulate enzyme-generated hydrogen peroxide reacting with bis-(2,4,6-trichlorophenyl) oxalate.&lt;/p&gt; &lt;p&gt;Linear correlations between hydrogen peroxide and chemilumenscent intensities yielded regression values greater than 0.9750 for hydrogen peroxide concentrations between 1.0 x 10&lt;sup&gt;-4&lt;/sup&gt; M and 1.0 x 10&lt;sup&gt;-1&lt;/sup&gt; M. The developed technique’s LOD was approximately 10 ppm. Variability of the prepared QD-polymer products was as low as 3.2% throughout all preparations.Stability of the preparations was tested during a 30-day period that displayed up to a four-fold increase in the first 10 days. The preparations were decently robust to the FIA system demonstrating up to a 15.20% intensity loss after twenty repetitive injections.&lt;/p&gt;","abstract_has_math":false,"creators":["Moore, Christopher S"],"institution":null,"degree_name":"MS (Master of Science)","degree_level":"Thesis - unrestricted","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-05-01T07:00:00Z","date_published":"2013-05-01T07:00:00Z","updated_at":"2026-07-24T02:19:59Z","subjects":["nanochemistry","quantum dot","immobilization","CdSe","peroxyoxalate","chemiluminescence","Analytical Chemistry","Bioimaging and Biomedical Optics","Nanoscience and Nanotechnology"],"languages":[],"rights":["Copyright by the authors."],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://dc.etsu.edu/etd/1151","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Moore, Christopher S"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-08T07:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - unrestricted"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS (Master of Science)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["nanochemistry","quantum dot","immobilization","CdSe","peroxyoxalate","chemiluminescence","Analytical Chemistry","Bioimaging and Biomedical Optics","Nanoscience and Nanotechnology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright by the authors."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://dc.etsu.edu/context/etd/article/2338/viewcontent/MooreC042913f.pdf","https://dc.etsu.edu/etd/1151"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Two batches of CdSe QDs with different sizes were synthesized for immobilizing in polyisoprene (PI), polymethylmethacrylate (PMMA), and low-density polyethylene (LDPE). The combinations of QDs and polymer substrates were evaluated for their analytical fit-for-use in applicable immunoassays. Hydrogen peroxide standards were injected into the flow injection analyzer (FIA) constructed to simulate enzyme-generated hydrogen peroxide reacting with bis-(2,4,6-trichlorophenyl) oxalate.</p> <p>Linear correlations between hydrogen peroxide and chemilumenscent intensities yielded regression values greater than 0.9750 for hydrogen peroxide concentrations between 1.0 x 10<sup>-4</sup> M and 1.0 x 10<sup>-1</sup> M. The developed technique’s LOD was approximately 10 ppm. Variability of the prepared QD-polymer products was as low as 3.2% throughout all preparations.Stability of the preparations was tested during a 30-day period that displayed up to a four-fold increase in the first 10 days. The preparations were decently robust to the FIA system demonstrating up to a 15.20% intensity loss after twenty repetitive injections.</p>"]},{"key":"dc:title","label":"Title","values":["Study of Immobilizing Cadmium Selenide Quantum Dots in Selected Polymers for Application in Peroxyoxalate Chemiluminescence Flow Injection Analysis"]}]}],"canonical_facts":{"dc:creator":["Moore, Christopher S"],"dc:date.available":["2013-04-08T07:00:00Z"],"dc:date.issued":["2013-05-01T07:00:00Z"],"dc:description.abstract":["<p>Two batches of CdSe QDs with different sizes were synthesized for immobilizing in polyisoprene (PI), polymethylmethacrylate (PMMA), and low-density polyethylene (LDPE). The combinations of QDs and polymer substrates were evaluated for their analytical fit-for-use in applicable immunoassays. Hydrogen peroxide standards were injected into the flow injection analyzer (FIA) constructed to simulate enzyme-generated hydrogen peroxide reacting with bis-(2,4,6-trichlorophenyl) oxalate.</p> <p>Linear correlations between hydrogen peroxide and chemilumenscent intensities yielded regression values greater than 0.9750 for hydrogen peroxide concentrations between 1.0 x 10<sup>-4</sup> M and 1.0 x 10<sup>-1</sup> M. The developed technique’s LOD was approximately 10 ppm. Variability of the prepared QD-polymer products was as low as 3.2% throughout all preparations.Stability of the preparations was tested during a 30-day period that displayed up to a four-fold increase in the first 10 days. The preparations were decently robust to the FIA system demonstrating up to a 15.20% intensity loss after twenty repetitive injections.</p>"],"dc:identifier":["https://dc.etsu.edu/context/etd/article/2338/viewcontent/MooreC042913f.pdf","https://dc.etsu.edu/etd/1151"],"dc:rights":["Copyright by the authors."],"dc:subject":["nanochemistry","quantum dot","immobilization","CdSe","peroxyoxalate","chemiluminescence","Analytical Chemistry","Bioimaging and Biomedical Optics","Nanoscience and Nanotechnology"],"dc:title":["Study of Immobilizing Cadmium Selenide Quantum Dots in Selected Polymers for Application in Peroxyoxalate Chemiluminescence Flow Injection Analysis"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Thesis - unrestricted"],"thesis:degree_name":["MS (Master of Science)"]},"updated_at":"2026-07-24T02:19:59Z"}