{"id":{"repo_id":"embry-riddle","oai_identifier":"oai:commons.erau.edu:edt-2034"},"canonical_url":"https://search.dev.ndltd.org/etd/embry-riddle/oai:commons.erau.edu:edt-2034","repository":{"repo_id":"embry-riddle","name":"Embry Riddle Aeronautical University","base_url":"https://commons.erau.edu/do/oai/"},"display":{"title":"Performance Review of Pipe to Structure Connections In Storm Water Infrastructure","abstract":"<p>This thesis evaluates the field performance of resilient pipe connectors used in the Florida Department of Transportation District 7 stormwater drainage infrastructure. These flexible rubber-based pipe-to-structure connections are intended to provide a watertight seal between drainage pipes and concrete structures such as manholes and ditch bottom inlets while allowing limited movement. Although resilient connectors were installed in District 7 as early as the 2000’s, no performance evaluation had been conducted until this study.</p> <p>Inspection locations were selected using project records, as-built plans, Google Maps, and feasibility of inspectable sites. Additional inspections were conducted in FDOT Districts 2 & 5 on traditional connections to evaluate their performance. Field inspections were completed using a Quickview<strong> </strong>AirHD [1] inspection camera to document pipe-to-structure connections and evaluate connection visibility, condition, and distress features. Observations were made based on visible signs of leakage or infiltration, cracking, material degradation, and grout coverage.</p> <p>Results showed that many resilient connectors remained visible and generally intact, although a substantial number of expected resilient connector locations were partially grouted over. Traditional connections were usually easier to identify visually because of the grout or mortar ring around the interface, but they more often exhibited distress such as cracking, material degradation, and leakage-related indicators. Overall, this study provides a field-based assessment of pipe-to-structure connection performance and supports continued inspection, monitoring, and improved installation practices for stormwater drainage systems.</p>","abstract_html":"&lt;p&gt;This thesis evaluates the field performance of resilient pipe connectors used in the Florida Department of Transportation District 7 stormwater drainage infrastructure. These flexible rubber-based pipe-to-structure connections are intended to provide a watertight seal between drainage pipes and concrete structures such as manholes and ditch bottom inlets while allowing limited movement. Although resilient connectors were installed in District 7 as early as the 2000’s, no performance evaluation had been conducted until this study.&lt;/p&gt; &lt;p&gt;Inspection locations were selected using project records, as-built plans, Google Maps, and feasibility of inspectable sites. Additional inspections were conducted in FDOT Districts 2 &amp; 5 on traditional connections to evaluate their performance. Field inspections were completed using a Quickview&lt;strong&gt; &lt;/strong&gt;AirHD [1] inspection camera to document pipe-to-structure connections and evaluate connection visibility, condition, and distress features. Observations were made based on visible signs of leakage or infiltration, cracking, material degradation, and grout coverage.&lt;/p&gt; &lt;p&gt;Results showed that many resilient connectors remained visible and generally intact, although a substantial number of expected resilient connector locations were partially grouted over. Traditional connections were usually easier to identify visually because of the grout or mortar ring around the interface, but they more often exhibited distress such as cracking, material degradation, and leakage-related indicators. Overall, this study provides a field-based assessment of pipe-to-structure connection performance and supports continued inspection, monitoring, and improved installation practices for stormwater drainage systems.&lt;/p&gt;","abstract_has_math":false,"creators":["Leo, Blake"],"institution":null,"degree_name":"Master of Science in Civil Engineering","degree_level":"Thesis - Open Access","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-04-01T07:00:00Z","date_published":"2026-04-01T07:00:00Z","updated_at":"2026-07-27T19:26:22Z","subjects":["Resilient Pipe Connector","Pipe-to-structure Connection","Stormwater Infrastructure","Resilient Pipe Connector Performance","Structural Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://commons.erau.edu/edt/990","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Leo, Blake"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2029-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis - Open Access"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Resilient Pipe Connector","Pipe-to-structure Connection","Stormwater Infrastructure","Resilient Pipe Connector Performance","Structural Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://commons.erau.edu/edt/990"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>This thesis evaluates the field performance of resilient pipe connectors used in the Florida Department of Transportation District 7 stormwater drainage infrastructure. These flexible rubber-based pipe-to-structure connections are intended to provide a watertight seal between drainage pipes and concrete structures such as manholes and ditch bottom inlets while allowing limited movement. Although resilient connectors were installed in District 7 as early as the 2000’s, no performance evaluation had been conducted until this study.</p> <p>Inspection locations were selected using project records, as-built plans, Google Maps, and feasibility of inspectable sites. Additional inspections were conducted in FDOT Districts 2 & 5 on traditional connections to evaluate their performance. Field inspections were completed using a Quickview<strong> </strong>AirHD [1] inspection camera to document pipe-to-structure connections and evaluate connection visibility, condition, and distress features. Observations were made based on visible signs of leakage or infiltration, cracking, material degradation, and grout coverage.</p> <p>Results showed that many resilient connectors remained visible and generally intact, although a substantial number of expected resilient connector locations were partially grouted over. Traditional connections were usually easier to identify visually because of the grout or mortar ring around the interface, but they more often exhibited distress such as cracking, material degradation, and leakage-related indicators. Overall, this study provides a field-based assessment of pipe-to-structure connection performance and supports continued inspection, monitoring, and improved installation practices for stormwater drainage systems.</p>"]},{"key":"dc:title","label":"Title","values":["Performance Review of Pipe to Structure Connections In Storm Water Infrastructure"]}]}],"canonical_facts":{"dc:creator":["Leo, Blake"],"dc:date.available":["2029-05-01T07:00:00Z"],"dc:description.abstract":["<p>This thesis evaluates the field performance of resilient pipe connectors used in the Florida Department of Transportation District 7 stormwater drainage infrastructure. These flexible rubber-based pipe-to-structure connections are intended to provide a watertight seal between drainage pipes and concrete structures such as manholes and ditch bottom inlets while allowing limited movement. Although resilient connectors were installed in District 7 as early as the 2000’s, no performance evaluation had been conducted until this study.</p> <p>Inspection locations were selected using project records, as-built plans, Google Maps, and feasibility of inspectable sites. Additional inspections were conducted in FDOT Districts 2 & 5 on traditional connections to evaluate their performance. Field inspections were completed using a Quickview<strong> </strong>AirHD [1] inspection camera to document pipe-to-structure connections and evaluate connection visibility, condition, and distress features. Observations were made based on visible signs of leakage or infiltration, cracking, material degradation, and grout coverage.</p> <p>Results showed that many resilient connectors remained visible and generally intact, although a substantial number of expected resilient connector locations were partially grouted over. Traditional connections were usually easier to identify visually because of the grout or mortar ring around the interface, but they more often exhibited distress such as cracking, material degradation, and leakage-related indicators. Overall, this study provides a field-based assessment of pipe-to-structure connection performance and supports continued inspection, monitoring, and improved installation practices for stormwater drainage systems.</p>"],"dc:identifier":["https://commons.erau.edu/edt/990"],"dc:subject":["Resilient Pipe Connector","Pipe-to-structure Connection","Stormwater Infrastructure","Resilient Pipe Connector Performance","Structural Engineering"],"dc:title":["Performance Review of Pipe to Structure Connections In Storm Water Infrastructure"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Thesis - Open Access"],"thesis:degree_name":["Master of Science in Civil Engineering"]},"updated_at":"2026-07-27T19:26:22Z"}