Embry Riddle Aeronautical University
Isolating Failure Mechanisms in a Fiberglass/Epoxy Tensile Test Specimen Using Acoustic Emission Signal Parameters
Abstract
dc:description.abstract<p>This study used acoustic emission (AE) signal parameters to isolate the failure mechanisms in a 0° unidirectional, fiberglass/epoxy tensile test specimen. Since several failure mechanisms were known to be present, the lack of any distinctly identifiable bands in the original amplitude distribution indicated that there was considerable overlap between the AE signals of the various failure mechanisms. In order to separate the amplitude bands associated with each mechanism, it was necessary to sort on the duration of the AE signal. Two additional plots, counts versus amplitude and hits versus counts, were used to verify that the amplitude distributions were comprised of a single predominant mechanism. A total of seven failure mechanisms were isolated from the original data set, all but two having a shape similar to that of a normal distribution.</p>
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Aerospace Engineering
- Level thesis:degree_level
- Thesis - Open Access
- Discipline thesis:degree_discipline
- Graduate Studies
- Year
- 1992
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kouvarakos, Michael
- Contributors dc:contributor
-
- Eric v. K. Hill
- David Kim
- James L. Walker II
Subjects
dc:subject × 4Identifiers
dc:identifier.*- Repository record dc:identifier
- https://commons.erau.edu/db-theses/267
- OAI identifier oai:identifier
- oai:commons.erau.edu:db-theses-1148