{"id":{"repo_id":"edithcowan","oai_identifier":"oai:ro.ecu.edu.au:theses-1141"},"canonical_url":"https://search.dev.ndltd.org/etd/edithcowan/oai:ro.ecu.edu.au:theses-1141","repository":{"repo_id":"edithcowan","name":"Edith Cowan University","base_url":"https://ro.ecu.edu.au/do/oai/"},"display":{"title":"Industrial heat stress : Using ice slurry ingestion as a practical approach to reducing heat strain in workers","abstract":"Personnel working in industry can encounter hot and humid conditions where uncompensable heat loads are experienced; an inability to dissipate stored heat increases the risk of developing a heat illness. In order to minimise the incidence of heat illnesses, several heat stress reduction interventions have been developed which aim to allow for safe repeated bouts of exposure to high thermal heat loads. These vary from modification of the working environment, wearing of personal protective equipment designed to cool, heat stress indices and/or hydration regimens. Despite these interventions, personnel still experience heat stress related illnesses. Consequently, the overall aim of the thesis was to quantify the cooling capacity of an ice slurry beverage, and to measure the physiological responses of this simple, easily implementable and cost effective cooling intervention.","abstract_html":"Personnel working in industry can encounter hot and humid conditions where uncompensable heat loads are experienced; an inability to dissipate stored heat increases the risk of developing a heat illness. In order to minimise the incidence of heat illnesses, several heat stress reduction interventions have been developed which aim to allow for safe repeated bouts of exposure to high thermal heat loads. These vary from modification of the working environment, wearing of personal protective equipment designed to cool, heat stress indices and/or hydration regimens. Despite these interventions, personnel still experience heat stress related illnesses. Consequently, the overall aim of the thesis was to quantify the cooling capacity of an ice slurry beverage, and to measure the physiological responses of this simple, easily implementable and cost effective cooling intervention.","abstract_has_math":false,"creators":["Maté, Joseph E."],"institution":"Edith Cowan University, Research Online, Perth, Western Australia","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-01-01T08:00:00Z","date_published":"2010-01-01T08:00:00Z","updated_at":"2026-07-27T19:21:48Z","subjects":["Thermoregulation","heat stress","ice slurry","occupational safety","Occupational Health and Industrial Hygiene"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://ro.ecu.edu.au/theses/141","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Maté, Joseph E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-01-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Edith Cowan University, Research Online, Perth, Western Australia"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thermoregulation","heat stress","ice slurry","occupational safety","Occupational Health and Industrial Hygiene"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://ro.ecu.edu.au/theses/141","https://ro.ecu.edu.au/context/theses/article/1141/viewcontent/Industrial_heat_stress___using_ice_slurry_ingestion_as_a_practica_Redacted.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Personnel working in industry can encounter hot and humid conditions where uncompensable heat loads are experienced; an inability to dissipate stored heat increases the risk of developing a heat illness. In order to minimise the incidence of heat illnesses, several heat stress reduction interventions have been developed which aim to allow for safe repeated bouts of exposure to high thermal heat loads. These vary from modification of the working environment, wearing of personal protective equipment designed to cool, heat stress indices and/or hydration regimens. Despite these interventions, personnel still experience heat stress related illnesses. Consequently, the overall aim of the thesis was to quantify the cooling capacity of an ice slurry beverage, and to measure the physiological responses of this simple, easily implementable and cost effective cooling intervention."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:source","label":"Dc Source","values":["Theses: Doctorates and Masters"]},{"key":"dc:title","label":"Title","values":["Industrial heat stress : Using ice slurry ingestion as a practical approach to reducing heat strain in workers"]}]}],"canonical_facts":{"dc:creator":["Maté, Joseph E."],"dc:date":["2010-01-01T08:00:00Z"],"dc:description":["Personnel working in industry can encounter hot and humid conditions where uncompensable heat loads are experienced; an inability to dissipate stored heat increases the risk of developing a heat illness. In order to minimise the incidence of heat illnesses, several heat stress reduction interventions have been developed which aim to allow for safe repeated bouts of exposure to high thermal heat loads. These vary from modification of the working environment, wearing of personal protective equipment designed to cool, heat stress indices and/or hydration regimens. Despite these interventions, personnel still experience heat stress related illnesses. Consequently, the overall aim of the thesis was to quantify the cooling capacity of an ice slurry beverage, and to measure the physiological responses of this simple, easily implementable and cost effective cooling intervention."],"dc:format":["application/pdf"],"dc:identifier":["https://ro.ecu.edu.au/theses/141","https://ro.ecu.edu.au/context/theses/article/1141/viewcontent/Industrial_heat_stress___using_ice_slurry_ingestion_as_a_practica_Redacted.pdf"],"dc:publisher":["Edith Cowan University, Research Online, Perth, Western Australia"],"dc:source":["Theses: Doctorates and Masters"],"dc:subject":["Thermoregulation","heat stress","ice slurry","occupational safety","Occupational Health and Industrial Hygiene"],"dc:title":["Industrial heat stress : Using ice slurry ingestion as a practical approach to reducing heat strain in workers"],"dc:type":["thesis"]},"updated_at":"2026-07-27T19:21:48Z"}