dc:description.abstract

Computer assisted skull re-assembly is an alternative to classical manual methods of physical restoration and reconstruction. The technique is reliant on high quality images produced by radiological CT or optical surface laser scans. The accuracy of CAD reassembly and the contribution the technologies of image production make to the process are largely unevaluated. This research uses four 3D models produced by a hand held laser scanner (Scorpion FASTSCAN by Polhemus) and one model produced by an automated, stationary laser scanner (Minolta by Hyperfocal) to re-assemble 5 skulls using a computer modelling program (Freeform Modelling). Hand held scanning, model production and quality are assessed; skull restoration accuracy is described and quantified by a reverse engineering software program (Geomagic Qualify) which measures overlap between the contour shells of original and restored skulls. The level of acceptable accuracy for skulls which might support facial reconstruction following re-assembly was determined to be < +/- 2.0 mm of error. Crania and mandibles were assessed individually. Accuracy results for five crania were unacceptable (40%), acceptable (40%), and reasonable (20%). Results for five mandibles demonstrated accuracy which was acceptable (40%), reasonable (20%), and good (40%). Optimising CAD potential for skull restoration depends on further research which examines: 1) the affect upon model quality resulting from the partnership between interdependent computer software, and 2) a comprehensive comparative analysis of surface capture technologies in relation to the models used in restoration.

Degree

thesis:*
Name dc:type.qualificationname
Master of Science
Level dc:type.qualificationlevel
Master's Thesis
Grantor dc:publisher.institution
University of Dundee
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mackenzie, Stenton

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
oai:discovery.dundee.ac.uk:studenttheses/3ec039a4-5826-4d4b-9a63-b6c977938ac8
OAI identifier oai:identifier
oai:discovery.dundee.ac.uk:studenttheses/3ec039a4-5826-4d4b-9a63-b6c977938ac8

Chain of custody

source
Harvested from
University of Dundee
Base URL
discovery.dundee.ac.uk/ws/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Mackenzie, Stenton. An evaluation of computer assisted skull re-assembly using hand held and automated laser scanners. Master's Thesis thesis, University of Dundee, 2007. https://discovery.dundee.ac.uk/en/studentTheses/3ec039a4-5826-4d4b-9a63-b6c977938ac8