Back to results

University of Dundee

Development of a Colonoscopy Simulator for the Evaluation of Colonoscopy Devices

Abstract

dc:description.abstract

Colonoscopy is the current standard for colorectal cancer screening. This procedure requires improvement since it causes patient pain and can even result in injury. Novel colonoscopy devices have to be evaluated to gain information about their performance. At the preclinical stage of the device development the evaluation is typically performed in laboratory experiments. For these experiments an artificial environment is required which can recreate the anatomical and biomechanical features of the colon.<br/><br/>A colonoscopy simulator for the evaluation of colonoscopy devices was developed within the ERC funded CoDIR project (Colonic Disease Investigation by Robotic Hydrocolonoscopy). The here developed simulator had to provide a colon phantom with realistic biomechanical properties as well as a sensor setup to measure signals which can be used to quantify the performance of devices which are tested within the simulator.<br/><br/>Related literature was reviewed and possible tissue mimicking materials were selected. The suitability of the selected materials was evaluated by testing the frictional and elastic properties of the materials and subsequently comparing the results to those of colon tissue. PVA cryogel was selected as the most suitable material as it exhibits comparable elasticity and coefficients of friction. The tissue mimicking materials were mould casted into phantoms which were designed to represent the anatomical features of the colon. A simulator environment was developed which integrates the phantom as well as force and pressure sensors into a functional system. The sensors measure mesenteric forces and intraluminal pressures which can be related to the performance of tested devices. The simulator allows the arrangement of the sensors and the phantoms in an adjustable, modular approach.<br/><br/>The simulator environment was successfully applied in the evaluation of a novel colonoscopy device. The results indicate that PVA cryogels exhibit unique mechanical properties which can be compared to those of colon tissue. The developed colonoscopy simulator provides a promising tool which can aid the development of novel colonoscopy devices.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy
Level dc:type.qualificationlevel
Doctoral Thesis
Grantor dc:publisher.institution
University of Dundee
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pakleppa, Markus
Advisors dc:contributor.advisor
  • Keatch, Robert
  • Vorstius, Jan

Subjects

dc:subject × 6

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
oai:discovery.dundee.ac.uk:studenttheses/33a20ce1-cb9e-4f55-8714-3f6762a16b75
OAI identifier oai:identifier
oai:discovery.dundee.ac.uk:studenttheses/33a20ce1-cb9e-4f55-8714-3f6762a16b75

Chain of custody

source
Harvested from
University of Dundee
Base URL
discovery.dundee.ac.uk/ws/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Pakleppa, Markus. Development of a Colonoscopy Simulator for the Evaluation of Colonoscopy Devices. Doctoral Thesis thesis, University of Dundee, 2016. https://discovery.dundee.ac.uk/en/studentTheses/33a20ce1-cb9e-4f55-8714-3f6762a16b75