{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-3293"},"canonical_url":"https://search.dev.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-3293","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"A Virtual Method for Establishing Femoral Stem Position in Total Hip Arthroplasty","abstract":"<p>Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed, in which the hip joint is reconstructed to improve functionality and decrease pain in the joint. Despite the success of these procedures, femoral stem misalignment remains an area that influences THA success. The relationship between the femoral stem geometry and implanted femoral stem size and orientation is underreported due to limitations in the collection of radiographic data used for clinical pre-operative templating. Furthermore, the influence of anatomic measurements on the direction and size of the femoral stem are not considered due to imaging technique and difficulties associated with reliably measuring, moreover are not reported. The overall goal was to develop a custom automated workflow to segment the intramedullary geometry and extract anatomic parameters from cadaveric femurs and to create an automated workflow for the implantation and evaluation of femoral stem positions.</p>","abstract_html":"&lt;p&gt;Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed, in which the hip joint is reconstructed to improve functionality and decrease pain in the joint. Despite the success of these procedures, femoral stem misalignment remains an area that influences THA success. The relationship between the femoral stem geometry and implanted femoral stem size and orientation is underreported due to limitations in the collection of radiographic data used for clinical pre-operative templating. Furthermore, the influence of anatomic measurements on the direction and size of the femoral stem are not considered due to imaging technique and difficulties associated with reliably measuring, moreover are not reported. The overall goal was to develop a custom automated workflow to segment the intramedullary geometry and extract anatomic parameters from cadaveric femurs and to create an automated workflow for the implantation and evaluation of femoral stem positions.&lt;/p&gt;","abstract_has_math":false,"creators":["Mattei, Samuel"],"institution":null,"degree_name":"M.S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chadd W. Clary","Casey A. Myers","Paul J. Rullkoetter","Matthew J. Rutherford"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-08-01T07:00:00Z","date_published":"2023-08-01T07:00:00Z","updated_at":"2026-07-24T02:01:39Z","subjects":["Anatomic measurements","Total hip arthroplasty","Virtual implantation","Biomechanical Engineering","Biomedical Engineering and Bioengineering","Engineering","Mechanical Engineering"],"languages":["English (eng)"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/2289","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chadd W. Clary","Casey A. Myers","Paul J. Rullkoetter","Matthew J. Rutherford"]},{"key":"dc:creator","label":"Author","values":["Mattei, Samuel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Anatomic measurements","Total hip arthroplasty","Virtual implantation","Biomechanical Engineering","Biomedical Engineering and Bioengineering","Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English (eng)"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/2289"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed, in which the hip joint is reconstructed to improve functionality and decrease pain in the joint. Despite the success of these procedures, femoral stem misalignment remains an area that influences THA success. The relationship between the femoral stem geometry and implanted femoral stem size and orientation is underreported due to limitations in the collection of radiographic data used for clinical pre-operative templating. Furthermore, the influence of anatomic measurements on the direction and size of the femoral stem are not considered due to imaging technique and difficulties associated with reliably measuring, moreover are not reported. The overall goal was to develop a custom automated workflow to segment the intramedullary geometry and extract anatomic parameters from cadaveric femurs and to create an automated workflow for the implantation and evaluation of femoral stem positions.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Virtual Method for Establishing Femoral Stem Position in Total Hip Arthroplasty"]}]}],"canonical_facts":{"dc:contributor":["Chadd W. Clary","Casey A. Myers","Paul J. Rullkoetter","Matthew J. Rutherford"],"dc:creator":["Mattei, Samuel"],"dc:description.abstract":["<p>Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed, in which the hip joint is reconstructed to improve functionality and decrease pain in the joint. Despite the success of these procedures, femoral stem misalignment remains an area that influences THA success. The relationship between the femoral stem geometry and implanted femoral stem size and orientation is underreported due to limitations in the collection of radiographic data used for clinical pre-operative templating. Furthermore, the influence of anatomic measurements on the direction and size of the femoral stem are not considered due to imaging technique and difficulties associated with reliably measuring, moreover are not reported. The overall goal was to develop a custom automated workflow to segment the intramedullary geometry and extract anatomic parameters from cadaveric femurs and to create an automated workflow for the implantation and evaluation of femoral stem positions.</p>"],"dc:format":["application/pdf"],"dc:identifier":["https://digitalcommons.du.edu/etd/2289"],"dc:language":["English (eng)"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:subject":["Anatomic measurements","Total hip arthroplasty","Virtual implantation","Biomechanical Engineering","Biomedical Engineering and Bioengineering","Engineering","Mechanical Engineering"],"dc:title":["A Virtual Method for Establishing Femoral Stem Position in Total Hip Arthroplasty"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M.S."]},"updated_at":"2026-07-24T02:01:39Z"}