{"id":{"repo_id":"denver","oai_identifier":"oai:digitalcommons.du.edu:etd-2797"},"canonical_url":"https://search.dev.ndltd.org/etd/denver/oai:digitalcommons.du.edu:etd-2797","repository":{"repo_id":"denver","name":"University of Denver","base_url":"https://digitalcommons.du.edu/do/oai/"},"display":{"title":"The Effects and Analysis of Implant Type and Surgical Approach in Total Hip Arthroplasty Dislocation Resistance","abstract":"<p>Total hip arthroplasty (THA) is one of the most successful orthopaedic surgeries performed, in which the hip joint is reconstructed to decrease pain and to improve the functionality to the joint. Although these surgeries are very successful, there still remain areas for improvement, such as failures due to instability and dislocation of the implanted joint. The purpose of this thesis is to investigate the effect of surgical entrance approach on dislocation, the effect of implant type, and the effect of capsule repair and closure. The need to quantify the resistance to dislocation is important in understanding the effect that each of these factors has on the total contribution to minimize the dislocation moment.</p>","abstract_html":"&lt;p&gt;Total hip arthroplasty (THA) is one of the most successful orthopaedic surgeries performed, in which the hip joint is reconstructed to decrease pain and to improve the functionality to the joint. Although these surgeries are very successful, there still remain areas for improvement, such as failures due to instability and dislocation of the implanted joint. The purpose of this thesis is to investigate the effect of surgical entrance approach on dislocation, the effect of implant type, and the effect of capsule repair and closure. The need to quantify the resistance to dislocation is important in understanding the effect that each of these factors has on the total contribution to minimize the dislocation moment.&lt;/p&gt;","abstract_has_math":false,"creators":["Marshall, Brittany"],"institution":null,"degree_name":"M. S.","degree_level":"Masters Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chadd W. Clary","Paul Rullkoetter","Margareta Stefanovic"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-01-01T08:00:00Z","date_published":"2020-01-01T08:00:00Z","updated_at":"2026-07-24T02:02:19Z","subjects":["Capsule repair","Dislocation resistance","Dual mobility","Surgical approach","Total hip arthroplasty","Biomechanical Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Mechanical Engineering"],"languages":["en"],"rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.du.edu/etd/1805","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chadd W. Clary","Paul Rullkoetter","Margareta Stefanovic"]},{"key":"dc:creator","label":"Author","values":["Marshall, Brittany"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-02-25T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M. S."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Capsule repair","Dislocation resistance","Dual mobility","Surgical approach","Total hip arthroplasty","Biomechanical Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.du.edu/etd/1805"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Total hip arthroplasty (THA) is one of the most successful orthopaedic surgeries performed, in which the hip joint is reconstructed to decrease pain and to improve the functionality to the joint. Although these surgeries are very successful, there still remain areas for improvement, such as failures due to instability and dislocation of the implanted joint. The purpose of this thesis is to investigate the effect of surgical entrance approach on dislocation, the effect of implant type, and the effect of capsule repair and closure. The need to quantify the resistance to dislocation is important in understanding the effect that each of these factors has on the total contribution to minimize the dislocation moment.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The Effects and Analysis of Implant Type and Surgical Approach in Total Hip Arthroplasty Dislocation Resistance"]}]}],"canonical_facts":{"dc:contributor":["Chadd W. Clary","Paul Rullkoetter","Margareta Stefanovic"],"dc:creator":["Marshall, Brittany"],"dc:date.available":["2021-02-25T08:00:00Z"],"dc:description.abstract":["<p>Total hip arthroplasty (THA) is one of the most successful orthopaedic surgeries performed, in which the hip joint is reconstructed to decrease pain and to improve the functionality to the joint. Although these surgeries are very successful, there still remain areas for improvement, such as failures due to instability and dislocation of the implanted joint. The purpose of this thesis is to investigate the effect of surgical entrance approach on dislocation, the effect of implant type, and the effect of capsule repair and closure. The need to quantify the resistance to dislocation is important in understanding the effect that each of these factors has on the total contribution to minimize the dislocation moment.</p>"],"dc:format":["application/pdf"],"dc:identifier":["https://digitalcommons.du.edu/etd/1805"],"dc:language":["en"],"dc:rights":["<p>Copyright is held by the author. User is responsible for all copyright compliance.</p>"],"dc:subject":["Capsule repair","Dislocation resistance","Dual mobility","Surgical approach","Total hip arthroplasty","Biomechanical Engineering","Biomechanics and Biotransport","Biomedical Engineering and Bioengineering","Mechanical Engineering"],"dc:title":["The Effects and Analysis of Implant Type and Surgical Approach in Total Hip Arthroplasty Dislocation Resistance"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["M. S."]},"updated_at":"2026-07-24T02:02:19Z"}