{"id":{"repo_id":"cuny","oai_identifier":"oai:academicworks.cuny.edu:cc_etds_theses-1700"},"canonical_url":"https://search.dev.ndltd.org/etd/cuny/oai:academicworks.cuny.edu:cc_etds_theses-1700","repository":{"repo_id":"cuny","name":"City University of New York - City College","base_url":"https://academicworks.cuny.edu/do/oai/"},"display":{"title":"An Experimental Study of Subcooled Flow Boiling at Elevated Pressure in an Annular Flow Channel","abstract":"<p>An experimental setup was developed to study the region of subcooled flow boiling. Multiple studies were carried out to investigate the effects of liquid velocity, pressure, and temperature on the boiling heat transfer of subcooled fluid flowing through a heated annular channel. Water was used as the working fluid and principle of Ohmic heating was used to raise water temperature. The system pressure, heat flux, & mass flux ranged from 101 to 912 kPa, 19 to 155 kW/m2, and 83 to 332 kg/m2-s, respectively. This report contains boiling curves, heat transfer coefficients of various studies and a description of the experimental setup.</p>","abstract_html":"&lt;p&gt;An experimental setup was developed to study the region of subcooled flow boiling. Multiple studies were carried out to investigate the effects of liquid velocity, pressure, and temperature on the boiling heat transfer of subcooled fluid flowing through a heated annular channel. Water was used as the working fluid and principle of Ohmic heating was used to raise water temperature. The system pressure, heat flux, &amp; mass flux ranged from 101 to 912 kPa, 19 to 155 kW/m2, and 83 to 332 kg/m2-s, respectively. This report contains boiling curves, heat transfer coefficients of various studies and a description of the experimental setup.&lt;/p&gt;","abstract_has_math":false,"creators":["Rahman, Pervej"],"institution":null,"degree_name":"Master of Engineering (M.E.)","degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Masahiro Kawaji","Feridun Delale"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-01-01T08:00:00Z","date_published":"2015-01-01T08:00:00Z","updated_at":"2026-07-24T01:57:14Z","subjects":["Subcooled flow boiling","Annular flow channel","Elevated pressure","Engineering","Mechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://academicworks.cuny.edu/cc_etds_theses/700","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Masahiro Kawaji","Feridun Delale"]},{"key":"dc:creator","label":"Author","values":["Rahman, Pervej"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2017-11-02T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering (M.E.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Subcooled flow boiling","Annular flow channel","Elevated pressure","Engineering","Mechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://academicworks.cuny.edu/cc_etds_theses/700"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>An experimental setup was developed to study the region of subcooled flow boiling. Multiple studies were carried out to investigate the effects of liquid velocity, pressure, and temperature on the boiling heat transfer of subcooled fluid flowing through a heated annular channel. Water was used as the working fluid and principle of Ohmic heating was used to raise water temperature. The system pressure, heat flux, & mass flux ranged from 101 to 912 kPa, 19 to 155 kW/m2, and 83 to 332 kg/m2-s, respectively. This report contains boiling curves, heat transfer coefficients of various studies and a description of the experimental setup.</p>"]},{"key":"dc:title","label":"Title","values":["An Experimental Study of Subcooled Flow Boiling at Elevated Pressure in an Annular Flow Channel"]}]}],"canonical_facts":{"dc:contributor":["Masahiro Kawaji","Feridun Delale"],"dc:creator":["Rahman, Pervej"],"dc:date.available":["2017-11-02T07:00:00Z"],"dc:description.abstract":["<p>An experimental setup was developed to study the region of subcooled flow boiling. Multiple studies were carried out to investigate the effects of liquid velocity, pressure, and temperature on the boiling heat transfer of subcooled fluid flowing through a heated annular channel. Water was used as the working fluid and principle of Ohmic heating was used to raise water temperature. The system pressure, heat flux, & mass flux ranged from 101 to 912 kPa, 19 to 155 kW/m2, and 83 to 332 kg/m2-s, respectively. This report contains boiling curves, heat transfer coefficients of various studies and a description of the experimental setup.</p>"],"dc:identifier":["https://academicworks.cuny.edu/cc_etds_theses/700"],"dc:subject":["Subcooled flow boiling","Annular flow channel","Elevated pressure","Engineering","Mechanical Engineering"],"dc:title":["An Experimental Study of Subcooled Flow Boiling at Elevated Pressure in an Annular Flow Channel"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Engineering (M.E.)"]},"updated_at":"2026-07-24T01:57:14Z"}