Back to results

Creighton University

Construction and Calibration of a Laboratory Ozonizer

Abstract

dc:description.abstract

In all branches of chemistry ozone has been found to be of considerable value. The addition of ozone to the ethylenic double bond, followed by reduction and the decomposition of the resulting ozonides, has been described (3) as the most general and reliable procedure for oxidative cleavage with simultaneous location of the double bond. The inorganic chemist has studied the action of ozone on various solvents (14) and on alkali metals, ammonia, and substituted ammonias (15). The biological chemist has employed ozone in small concentrations as a disinfectant, and industrial engineers have labored to combat its toxicity concentrations (9). |Although ozone was discovered as early as 1785, its usefulness has been realized only within the last forty- five years. In spite of Its relatively unknown uses and possibilities in the chemical field to the average person, most of them have experienced Its presence without knowing it. Ozone occurs in the vicinity of electrical field transformers and transmitters, or any region of an electrical discharge in air. It is detectable after an electrical storm because its presence gives the air a|fresh odor. |Previous laboratory ozonizers have been constructed using varying amounts of secondary voltages, soft and pyrex glass tubing, different amounts of surface area over which the oxygen passes, various conducting mediums and electrodes, and some have made the conversion from pure oxygen while others have used air as the source of oxygen. Every ozonizer is slightly different from all others in construction as well as in percent conversion. The purpose of this investigation was to construct an ozonizer and to calibrate the percent conversion of oxygen to ozone.

Degree

thesis:*
Grantor dc:publisher
Creighton University
Year dc:date.issued
1953

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bottomley, William K.
Advisor dc:contributor.advisor
  • Baumann, Donald J.

Rights

dc:rights
Statement dc:rights
  • A non-exclusive distribution right is granted to Creighton University and to ProQuest following the publishing model selected above.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10504/106900
OAI identifier oai:identifier
oai:cdr.creighton.edu:10504/106900

Chain of custody

source
Harvested from
Creighton University
Base URL
cdr.creighton.edu/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Bottomley, William K.. Construction and Calibration of a Laboratory Ozonizer. Creighton University, 1953. http://hdl.handle.net/10504/106900