Back to results

Cranfield University

A study of FT-IR spectroscopy for the identification and classifcation of haematological malignancies

Abstract

dc:description.abstract

The aim of the work presented in this thesis was to explore the use of FT-IR spectroscopy, as a complementary clinical tool for haematological laboratory analysis. FT-IR spectra were measured from air-dried and frozen cell lines derived from lymphoma, lymphoid, myeloid leukaemia and normal and chronic lymphocytic leukaemia blood samples. Multivariate statistical analysis was used to extract important spectral information with the greatest discriminative power. Principal component fed linear discriminant spectral models have been tested with leave one out cross validation procedures. A preliminary unfiltered classification model using 50 frozen and air-dried samples correctly classified 54% of 18556 spectra. The performance improved with the three cell line group datasets, with 71% of 19903 spectra correctly classified. Furthermore, the use of the frozen spectra improved the performance of the three cell line group classification model considerably. Findings showed that 73.3% of 9920 spectra were correctly classified in the frozen datasets, whereas in the air-dried only 41.5% of 9983 spectra are correctly classified. Optimisation of the spectral models by selection of principal components, application of Savitsky-Golay filters and selecting spectra using standard deviation and absorption filter tool was investigated. Using the first 25 significant PCs, a 0 th derivative Savitsky-Golay filter and the absorbance filter tool on the frozen five cell line spectral dataset were shown to be the optimal parameters for constructing a classification model. When tested with leave one batch out cross validation 90% of the spectra were correctly classified for the five cell line model. Blood component classification models tested with leave one batch out cross validation performed well. The whole blood model correctly classified 70% of 1736 spectra, measured on 22 samples. The plasma model correctly classified 80.6% of 331 spectra and the buffy coat model correctly classified 99.5% of 1438 spectra. This demonstrated that the buffy coat (containing white blood cells) holds the key biochemical information for discrimination between the pathology of the blood samples. Partial least squares analysis has been demonstrated as a method to support whole blood count tests for real time prediction of cellular constituents. These findings demonstrate the potential of FT- IR spectroscopy as a clinical tool although more work is needed if it is to be applied in clinical practice.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Babrah, Jaspreet
Advisors dc:contributor.advisor
  • Stone, Nicholas
  • Bessant, Conrad

Rights

dc:rights
Statement dc:rights
  • © Cranfield University 2005. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
http://dspace.lib.cranfield.ac.uk/handle/1826/4594
OAI identifier oai:identifier
oai:dspace.lib.cranfield.ac.uk:1826/4594

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
related terms
citation

Babrah, Jaspreet. A study of FT-IR spectroscopy for the identification and classifcation of haematological malignancies. Cranfield University, 2009. http://dspace.lib.cranfield.ac.uk/handle/1826/4594