{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/82603"},"canonical_url":"https://search.dev.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/82603","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Occupational dose assessment of 64Cu-ATSM in a veterinary setting","abstract":"64Cu-ATSM is an emerging radiopharmaceutical for diagnostic use in Positron Emission Tomography (PET) and has potential utility for radiation therapy but to date there are no studies that assess the occupational doses delivered to workers in either a hospital or veterinary environment. This study consisted of canine patients that were recruited at the Colorado State University James L. Voss Veterinary Teaching Hospital (VTH). The study was aimed at determining the radiation dose to veterinary workers from clinical PET/CT procedures using 64Cu-ATSM. To determine the dose to the workers, each worker was assigned two Electronic Personal Dosimeters (EPDs) to be worn on the chest and waist during the entirety of each procedure. The workers monitored during this study involved included a radiobiologist, a nuclear medicine technician, an anesthesiologist, and a veterinary surgeon. Seven canine patients were imaged over a ten month period with an average mass of 33.7 kg (a range of 20.0 - 55.1 kg) with an average injected activity of 5 MBq kg-1. The dose range for the radiobiologist was 2 -17 µSv, for the nuclear medicine technician 0 -14 µSv, for the anesthesiologist 0 - 12 µSv, and for the surgeon 0 -10 µSv. In a comparison between the results of this study and published literature on occupational exposures from human/veterinary FDG PET/CT procedures, 64Cu-ATSM veterinary PET/CT procedures, on a per patient bias, exposed workers to less radiation.","abstract_html":"64Cu-ATSM is an emerging radiopharmaceutical for diagnostic use in Positron Emission Tomography (PET) and has potential utility for radiation therapy but to date there are no studies that assess the occupational doses delivered to workers in either a hospital or veterinary environment. This study consisted of canine patients that were recruited at the Colorado State University James L. Voss Veterinary Teaching Hospital (VTH). The study was aimed at determining the radiation dose to veterinary workers from clinical PET/CT procedures using 64Cu-ATSM. To determine the dose to the workers, each worker was assigned two Electronic Personal Dosimeters (EPDs) to be worn on the chest and waist during the entirety of each procedure. The workers monitored during this study involved included a radiobiologist, a nuclear medicine technician, an anesthesiologist, and a veterinary surgeon. Seven canine patients were imaged over a ten month period with an average mass of 33.7 kg (a range of 20.0 - 55.1 kg) with an average injected activity of 5 MBq kg-1. The dose range for the radiobiologist was 2 -17 µSv, for the nuclear medicine technician 0 -14 µSv, for the anesthesiologist 0 - 12 µSv, and for the surgeon 0 -10 µSv. In a comparison between the results of this study and published literature on occupational exposures from human/veterinary FDG PET/CT procedures, 64Cu-ATSM veterinary PET/CT procedures, on a per patient bias, exposed workers to less radiation.","abstract_has_math":false,"creators":["Hetrick, Lucas, author","Johnson, Thomas, advisor","Kraft, Susan, committee member","Biller, Barbara, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-07-27T19:13:06Z","subjects":["64Cu-ATSM","veterinary","radiation","occupational exposure"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.25675/3.018569"],"render_values":[{"text":"https://doi.org/10.25675/3.018569","href":"https://doi.org/10.25675/3.018569","code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10217/82603","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hetrick, Lucas, author","Johnson, Thomas, advisor","Kraft, Susan, committee member","Biller, Barbara, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T06:42:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-03T06:42:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["64Cu-ATSM","veterinary","radiation","occupational exposure"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Hetrick_colostate_0053N_12356.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/82603","https://doi.org/10.25675/3.018569"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["64Cu-ATSM is an emerging radiopharmaceutical for diagnostic use in Positron Emission Tomography (PET) and has potential utility for radiation therapy but to date there are no studies that assess the occupational doses delivered to workers in either a hospital or veterinary environment. This study consisted of canine patients that were recruited at the Colorado State University James L. Voss Veterinary Teaching Hospital (VTH). The study was aimed at determining the radiation dose to veterinary workers from clinical PET/CT procedures using 64Cu-ATSM. To determine the dose to the workers, each worker was assigned two Electronic Personal Dosimeters (EPDs) to be worn on the chest and waist during the entirety of each procedure. The workers monitored during this study involved included a radiobiologist, a nuclear medicine technician, an anesthesiologist, and a veterinary surgeon. Seven canine patients were imaged over a ten month period with an average mass of 33.7 kg (a range of 20.0 - 55.1 kg) with an average injected activity of 5 MBq kg-1. The dose range for the radiobiologist was 2 -17 µSv, for the nuclear medicine technician 0 -14 µSv, for the anesthesiologist 0 - 12 µSv, and for the surgeon 0 -10 µSv. In a comparison between the results of this study and published literature on occupational exposures from human/veterinary FDG PET/CT procedures, 64Cu-ATSM veterinary PET/CT procedures, on a per patient bias, exposed workers to less radiation."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Occupational dose assessment of 64Cu-ATSM in a veterinary setting"]}]}],"canonical_facts":{"dc:creator":["Hetrick, Lucas, author","Johnson, Thomas, advisor","Kraft, Susan, committee member","Biller, Barbara, committee member"],"dc:date.accessioned":["2007-01-03T06:42:49Z"],"dc:date.available":["2007-01-03T06:42:49Z"],"dc:date.issued":["2014"],"dc:description.abstract":["64Cu-ATSM is an emerging radiopharmaceutical for diagnostic use in Positron Emission Tomography (PET) and has potential utility for radiation therapy but to date there are no studies that assess the occupational doses delivered to workers in either a hospital or veterinary environment. This study consisted of canine patients that were recruited at the Colorado State University James L. Voss Veterinary Teaching Hospital (VTH). The study was aimed at determining the radiation dose to veterinary workers from clinical PET/CT procedures using 64Cu-ATSM. To determine the dose to the workers, each worker was assigned two Electronic Personal Dosimeters (EPDs) to be worn on the chest and waist during the entirety of each procedure. The workers monitored during this study involved included a radiobiologist, a nuclear medicine technician, an anesthesiologist, and a veterinary surgeon. Seven canine patients were imaged over a ten month period with an average mass of 33.7 kg (a range of 20.0 - 55.1 kg) with an average injected activity of 5 MBq kg-1. The dose range for the radiobiologist was 2 -17 µSv, for the nuclear medicine technician 0 -14 µSv, for the anesthesiologist 0 - 12 µSv, and for the surgeon 0 -10 µSv. In a comparison between the results of this study and published literature on occupational exposures from human/veterinary FDG PET/CT procedures, 64Cu-ATSM veterinary PET/CT procedures, on a per patient bias, exposed workers to less radiation."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["Hetrick_colostate_0053N_12356.pdf"],"dc:identifier.uri":["http://hdl.handle.net/10217/82603","https://doi.org/10.25675/3.018569"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."],"dc:subject":["64Cu-ATSM","veterinary","radiation","occupational exposure"],"dc:title":["Occupational dose assessment of 64Cu-ATSM in a veterinary setting"],"dc:type":["Text"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-07-27T19:13:06Z"}