{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/79039"},"canonical_url":"https://search.dev.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/79039","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"The rate of decay of fresh fission products from a nuclear reactor","abstract":"Determining the rate of decay of fresh fission products from a nuclear reactor is complex because of the number of isotopes involved, different types of decay, half-lives of the isotopes, and some isotopes decay into other radioactive isotopes. Traditionally, a simplified rule of t-1.2 or 7s and 10s is used to determine the dose rate from nuclear weapons and can be to estimate the dose rate from fresh fission products of a nuclear reactor. An experiment was designed to determine the dose rate with respect to time from fresh fission products of a nuclear reactor. The experiment exposed 0.5 grams of U3O8 to a fast and thermal neutron flux from a TRIGA Research Reactor (Lakewood, CO) for ten minutes. The dose rate from the fission products was measured by four Mirion DMC 2000XB electronic personal dosimeters over a period of six days. The resulting dose rate with respect to time had a slope of t-1.024 and could be simplified to a rule of 10s: the does rate of fresh fission products from a nuclear reactor decreases by a factor of 10 for every 10 units of time.","abstract_html":"Determining the rate of decay of fresh fission products from a nuclear reactor is complex because of the number of isotopes involved, different types of decay, half-lives of the isotopes, and some isotopes decay into other radioactive isotopes. Traditionally, a simplified rule of t-1.2 or 7s and 10s is used to determine the dose rate from nuclear weapons and can be to estimate the dose rate from fresh fission products of a nuclear reactor. An experiment was designed to determine the dose rate with respect to time from fresh fission products of a nuclear reactor. The experiment exposed 0.5 grams of U3O8 to a fast and thermal neutron flux from a TRIGA Research Reactor (Lakewood, CO) for ten minutes. The dose rate from the fission products was measured by four Mirion DMC 2000XB electronic personal dosimeters over a period of six days. The resulting dose rate with respect to time had a slope of t-1.024 and could be simplified to a rule of 10s: the does rate of fresh fission products from a nuclear reactor decreases by a factor of 10 for every 10 units of time.","abstract_has_math":false,"creators":["Dolan, David J., author","Johnson, Thomas, advisor","Brandl, Alexander, committee member","Desir, Rosemond, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Environmental and Radiological Health Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-07-27T19:13:18Z","subjects":["dose rate","nuclear reactor","fission products"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.25675/3.018833"],"render_values":[{"text":"https://doi.org/10.25675/3.018833","href":"https://doi.org/10.25675/3.018833","code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10217/79039","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Dolan, David J., author","Johnson, Thomas, advisor","Brandl, Alexander, committee member","Desir, Rosemond, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T05:00:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-01-03T05:00:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental and Radiological Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dose rate","nuclear reactor","fission products"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Dolan_colostate_0053N_11593.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/79039","https://doi.org/10.25675/3.018833"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Determining the rate of decay of fresh fission products from a nuclear reactor is complex because of the number of isotopes involved, different types of decay, half-lives of the isotopes, and some isotopes decay into other radioactive isotopes. Traditionally, a simplified rule of t-1.2 or 7s and 10s is used to determine the dose rate from nuclear weapons and can be to estimate the dose rate from fresh fission products of a nuclear reactor. An experiment was designed to determine the dose rate with respect to time from fresh fission products of a nuclear reactor. The experiment exposed 0.5 grams of U3O8 to a fast and thermal neutron flux from a TRIGA Research Reactor (Lakewood, CO) for ten minutes. The dose rate from the fission products was measured by four Mirion DMC 2000XB electronic personal dosimeters over a period of six days. The resulting dose rate with respect to time had a slope of t-1.024 and could be simplified to a rule of 10s: the does rate of fresh fission products from a nuclear reactor decreases by a factor of 10 for every 10 units of time."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["The rate of decay of fresh fission products from a nuclear reactor"]}]}],"canonical_facts":{"dc:creator":["Dolan, David J., author","Johnson, Thomas, advisor","Brandl, Alexander, committee member","Desir, Rosemond, committee member"],"dc:date.accessioned":["2007-01-03T05:00:12Z"],"dc:date.available":["2007-01-03T05:00:12Z"],"dc:date.issued":["2013"],"dc:description.abstract":["Determining the rate of decay of fresh fission products from a nuclear reactor is complex because of the number of isotopes involved, different types of decay, half-lives of the isotopes, and some isotopes decay into other radioactive isotopes. Traditionally, a simplified rule of t-1.2 or 7s and 10s is used to determine the dose rate from nuclear weapons and can be to estimate the dose rate from fresh fission products of a nuclear reactor. An experiment was designed to determine the dose rate with respect to time from fresh fission products of a nuclear reactor. The experiment exposed 0.5 grams of U3O8 to a fast and thermal neutron flux from a TRIGA Research Reactor (Lakewood, CO) for ten minutes. The dose rate from the fission products was measured by four Mirion DMC 2000XB electronic personal dosimeters over a period of six days. The resulting dose rate with respect to time had a slope of t-1.024 and could be simplified to a rule of 10s: the does rate of fresh fission products from a nuclear reactor decreases by a factor of 10 for every 10 units of time."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["Dolan_colostate_0053N_11593.pdf"],"dc:identifier.uri":["http://hdl.handle.net/10217/79039","https://doi.org/10.25675/3.018833"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."],"dc:subject":["dose rate","nuclear reactor","fission products"],"dc:title":["The rate of decay of fresh fission products from a nuclear reactor"],"dc:type":["Text"],"thesis:degree_discipline":["Environmental and Radiological Health Sciences"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-07-27T19:13:18Z"}