{"id":{"repo_id":"colostate","oai_identifier":"oai:mountainscholar.org:10217/73667"},"canonical_url":"https://search.dev.ndltd.org/etd/colostate/oai:mountainscholar.org:10217/73667","repository":{"repo_id":"colostate","name":"Colorado State University","base_url":"https://api.mountainscholar.org/server/oai/request"},"display":{"title":"Occurrence of cyclo-siloxanes in wastewater treatment plants - quantification and monitoring","abstract":"Siloxanes are persistent, bio-accumulative and toxic emerging contaminants introduced to wastewater from common healthcare and biomedical products, and various industrial processes. They remain unchanged through wastewater treatment and a considerable portion ends up in surface waters through effluent discharge. 30 to 60 ng/L Decamethylcyclopentasiloxane (D5) was detected in two UK Rivers, while ~400 ng/L of D5 may be found in wastewater effluents. Hence, siloxanes are under consideration by Canadian Environmental Assessment Agency and UK Environment Agency for drinking water regulations. Siloxanes are hydrophobic and also accumulate in activated sludge and biogas, causing mechanical problems due to scaling. This research aims: to quantify the siloxanes in sludge samples obtained from Loveland, CO wastewater treatment plant (WWTP); and to study their removal. A method was developed to effectively extract siloxanes from activated sludge samples using liquid extraction followed by quantification with gas chromatography/mass spectrometry. Results for Loveland Wastewater Treatment Plant samples indicated that Octamethylcyclotetrasiloxane (D4) and Decamethylcyclopentasiloxane D5 are present up to 17.11 µg/g dried-sludge. The effectiveness of H2O2 in siloxane removal was investigated. Sludge samples were spiked with D4 and D5 at 12 mg/g and were treated with 1ml, 3ml, and 5ml of 30% H2O2 for 1hr, 2hr, and 3hr reaction time each. Results indicated a 72% reduction in D4 and D5 levels after 3 hrs.","abstract_html":"Siloxanes are persistent, bio-accumulative and toxic emerging contaminants introduced to wastewater from common healthcare and biomedical products, and various industrial processes. They remain unchanged through wastewater treatment and a considerable portion ends up in surface waters through effluent discharge. 30 to 60 ng/L Decamethylcyclopentasiloxane (D5) was detected in two UK Rivers, while ~400 ng/L of D5 may be found in wastewater effluents. Hence, siloxanes are under consideration by Canadian Environmental Assessment Agency and UK Environment Agency for drinking water regulations. Siloxanes are hydrophobic and also accumulate in activated sludge and biogas, causing mechanical problems due to scaling. This research aims: to quantify the siloxanes in sludge samples obtained from Loveland, CO wastewater treatment plant (WWTP); and to study their removal. A method was developed to effectively extract siloxanes from activated sludge samples using liquid extraction followed by quantification with gas chromatography/mass spectrometry. Results for Loveland Wastewater Treatment Plant samples indicated that Octamethylcyclotetrasiloxane (D4) and Decamethylcyclopentasiloxane D5 are present up to 17.11 µg/g dried-sludge. The effectiveness of H2O2 in siloxane removal was investigated. Sludge samples were spiked with D4 and D5 at 12 mg/g and were treated with 1ml, 3ml, and 5ml of 30% H2O2 for 1hr, 2hr, and 3hr reaction time each. Results indicated a 72% reduction in D4 and D5 levels after 3 hrs.","abstract_has_math":false,"creators":["Kulkarni, Harshad Vijay, author","Omur-Ozbek, Pinar, advisor","Carlson, Kenneth, committee member","Dooley, Gregory, committee member"],"institution":"Colorado State University. Libraries","degree_name":"Master of Science (M.S.)","degree_level":"Masters","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-07-27T19:13:20Z","subjects":["cogeneration","wastewater utilities","gas chromatography-mass spectrometry","cyclosiloxanes","biogas"],"languages":["eng","English"],"rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.25675/3.018907"],"render_values":[{"text":"https://doi.org/10.25675/3.018907","href":"https://doi.org/10.25675/3.018907","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["ETDF2012400430CVEE"],"render_values":[{"text":"ETDF2012400430CVEE","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10217/73667","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kulkarni, Harshad Vijay, author","Omur-Ozbek, Pinar, advisor","Carlson, Kenneth, committee member","Dooley, Gregory, committee member"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-01-03T08:34:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-01-01T08:10:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Colorado State University. Libraries"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.S.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["cogeneration","wastewater utilities","gas chromatography-mass spectrometry","cyclosiloxanes","biogas"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["KULKARNI_colostate_0053N_11561.pdf","ETDF2012400430CVEE"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10217/73667","https://doi.org/10.25675/3.018907"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Siloxanes are persistent, bio-accumulative and toxic emerging contaminants introduced to wastewater from common healthcare and biomedical products, and various industrial processes. They remain unchanged through wastewater treatment and a considerable portion ends up in surface waters through effluent discharge. 30 to 60 ng/L Decamethylcyclopentasiloxane (D5) was detected in two UK Rivers, while ~400 ng/L of D5 may be found in wastewater effluents. Hence, siloxanes are under consideration by Canadian Environmental Assessment Agency and UK Environment Agency for drinking water regulations. Siloxanes are hydrophobic and also accumulate in activated sludge and biogas, causing mechanical problems due to scaling. This research aims: to quantify the siloxanes in sludge samples obtained from Loveland, CO wastewater treatment plant (WWTP); and to study their removal. A method was developed to effectively extract siloxanes from activated sludge samples using liquid extraction followed by quantification with gas chromatography/mass spectrometry. Results for Loveland Wastewater Treatment Plant samples indicated that Octamethylcyclotetrasiloxane (D4) and Decamethylcyclopentasiloxane D5 are present up to 17.11 µg/g dried-sludge. The effectiveness of H2O2 in siloxane removal was investigated. Sludge samples were spiked with D4 and D5 at 12 mg/g and were treated with 1ml, 3ml, and 5ml of 30% H2O2 for 1hr, 2hr, and 3hr reaction time each. Results indicated a 72% reduction in D4 and D5 levels after 3 hrs."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","masters theses"]},{"key":"dc:title","label":"Title","values":["Occurrence of cyclo-siloxanes in wastewater treatment plants - quantification and monitoring"]}]}],"canonical_facts":{"dc:creator":["Kulkarni, Harshad Vijay, author","Omur-Ozbek, Pinar, advisor","Carlson, Kenneth, committee member","Dooley, Gregory, committee member"],"dc:date.accessioned":["2007-01-03T08:34:07Z"],"dc:date.available":["2014-01-01T08:10:42Z"],"dc:date.issued":["2012"],"dc:description.abstract":["Siloxanes are persistent, bio-accumulative and toxic emerging contaminants introduced to wastewater from common healthcare and biomedical products, and various industrial processes. They remain unchanged through wastewater treatment and a considerable portion ends up in surface waters through effluent discharge. 30 to 60 ng/L Decamethylcyclopentasiloxane (D5) was detected in two UK Rivers, while ~400 ng/L of D5 may be found in wastewater effluents. Hence, siloxanes are under consideration by Canadian Environmental Assessment Agency and UK Environment Agency for drinking water regulations. Siloxanes are hydrophobic and also accumulate in activated sludge and biogas, causing mechanical problems due to scaling. This research aims: to quantify the siloxanes in sludge samples obtained from Loveland, CO wastewater treatment plant (WWTP); and to study their removal. A method was developed to effectively extract siloxanes from activated sludge samples using liquid extraction followed by quantification with gas chromatography/mass spectrometry. Results for Loveland Wastewater Treatment Plant samples indicated that Octamethylcyclotetrasiloxane (D4) and Decamethylcyclopentasiloxane D5 are present up to 17.11 µg/g dried-sludge. The effectiveness of H2O2 in siloxane removal was investigated. Sludge samples were spiked with D4 and D5 at 12 mg/g and were treated with 1ml, 3ml, and 5ml of 30% H2O2 for 1hr, 2hr, and 3hr reaction time each. Results indicated a 72% reduction in D4 and D5 levels after 3 hrs."],"dc:format.medium":["born digital","masters theses"],"dc:identifier":["KULKARNI_colostate_0053N_11561.pdf","ETDF2012400430CVEE"],"dc:identifier.uri":["http://hdl.handle.net/10217/73667","https://doi.org/10.25675/3.018907"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado State University. Libraries"],"dc:rights":["Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright."],"dc:subject":["cogeneration","wastewater utilities","gas chromatography-mass spectrometry","cyclosiloxanes","biogas"],"dc:title":["Occurrence of cyclo-siloxanes in wastewater treatment plants - quantification and monitoring"],"dc:type":["Text"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science (M.S.)"],"thesis:institution_name":["Colorado State University"]},"updated_at":"2026-07-27T19:13:20Z"}