{"id":{"repo_id":"colo-mines","oai_identifier":"oai:repository.mines.edu:11124/173293"},"canonical_url":"https://search.dev.ndltd.org/etd/colo-mines/oai:repository.mines.edu:11124/173293","repository":{"repo_id":"colo-mines","name":"Colorado School of Mines","base_url":"https://repository.mines.edu/server/oai/request"},"display":{"title":"Computational modeling of extravascular platelet aggregation under flow","abstract":"Platelets in blood aggregate as part of the normal physiologic response to a blood vessel injury. Extravascular injuries, those that occur outside the blood vessel, are not well understood and lack numerical tools to study them. In this research, we develop and validate numerical tools to study extravascular platelet aggregation based on the design of a microfluidic \"bleeding chip'' device via the finite element method. Key model developments are for the fluid dynamics and platelet transport. For the platelet transport model, we also develop and benchmark the underlying flux-corrected transport algorithm to run in parallel using the FEniCS software suite. We use the numerical tools developed to calibrate and validate an ODE model of extravascular aggregation. With this model, we also benchmark and test the disparity of the fluid and reaction timescales to improve simulation time. These numerical tools provide a framework for future studies in extravascular platelet aggregation and other blood clotting phenomena.","abstract_html":"Platelets in blood aggregate as part of the normal physiologic response to a blood vessel injury. Extravascular injuries, those that occur outside the blood vessel, are not well understood and lack numerical tools to study them. In this research, we develop and validate numerical tools to study extravascular platelet aggregation based on the design of a microfluidic &quot;bleeding chip&#x27;&#x27; device via the finite element method. Key model developments are for the fluid dynamics and platelet transport. For the platelet transport model, we also develop and benchmark the underlying flux-corrected transport algorithm to run in parallel using the FEniCS software suite. We use the numerical tools developed to calibrate and validate an ODE model of extravascular aggregation. With this model, we also benchmark and test the disparity of the fluid and reaction timescales to improve simulation time. These numerical tools provide a framework for future studies in extravascular platelet aggregation and other blood clotting phenomena.","abstract_has_math":false,"creators":["Danes, Nicholas Archimedes"],"institution":"Colorado School of Mines. Arthur Lakes Library","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Applied Mathematics and Statistics","degree_department":null,"school":null,"contributors":[],"advisors":["Leiderman, Karin","Sitaraman, Hariswaran"],"committee_chairs":[],"committee_members":["Neeves, Keith B.","Ganesh, Mahadevan","Pankavich, Stephen"],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-07-24T01:42:00Z","subjects":[],"languages":["eng","English"],"rights":["Copyright of the original work is retained by the author."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["T 8809"],"render_values":[{"text":"T 8809","href":null,"code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/11124/173293","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Leiderman, Karin","Sitaraman, Hariswaran"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Neeves, Keith B.","Ganesh, Mahadevan","Pankavich, Stephen"]},{"key":"dc:creator","label":"Author","values":["Danes, Nicholas Archimedes"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-10-15T17:46:35Z","2022-02-03T13:16:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-04-09T17:46:38Z","2022-02-03T13:16:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Colorado School of Mines. Arthur Lakes Library"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Mathematics and Statistics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Colorado School of Mines"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright of the original work is retained by the author."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["Danes_mines_0052E_11823.pdf","T 8809"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11124/173293"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Includes bibliographical references.","2019 Fall."]},{"key":"dc:description.abstract","label":"Abstract","values":["Platelets in blood aggregate as part of the normal physiologic response to a blood vessel injury. Extravascular injuries, those that occur outside the blood vessel, are not well understood and lack numerical tools to study them. In this research, we develop and validate numerical tools to study extravascular platelet aggregation based on the design of a microfluidic \"bleeding chip'' device via the finite element method. Key model developments are for the fluid dynamics and platelet transport. For the platelet transport model, we also develop and benchmark the underlying flux-corrected transport algorithm to run in parallel using the FEniCS software suite. We use the numerical tools developed to calibrate and validate an ODE model of extravascular aggregation. With this model, we also benchmark and test the disparity of the fluid and reaction timescales to improve simulation time. These numerical tools provide a framework for future studies in extravascular platelet aggregation and other blood clotting phenomena."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["born digital","doctoral dissertations"]},{"key":"dc:title","label":"Title","values":["Computational modeling of extravascular platelet aggregation under flow"]}]}],"canonical_facts":{"dc:contributor.advisor":["Leiderman, Karin","Sitaraman, Hariswaran"],"dc:contributor.committeemember":["Neeves, Keith B.","Ganesh, Mahadevan","Pankavich, Stephen"],"dc:creator":["Danes, Nicholas Archimedes"],"dc:date.accessioned":["2019-10-15T17:46:35Z","2022-02-03T13:16:46Z"],"dc:date.available":["2020-04-09T17:46:38Z","2022-02-03T13:16:46Z"],"dc:date.issued":["2019"],"dc:description":["Includes bibliographical references.","2019 Fall."],"dc:description.abstract":["Platelets in blood aggregate as part of the normal physiologic response to a blood vessel injury. Extravascular injuries, those that occur outside the blood vessel, are not well understood and lack numerical tools to study them. In this research, we develop and validate numerical tools to study extravascular platelet aggregation based on the design of a microfluidic \"bleeding chip'' device via the finite element method. Key model developments are for the fluid dynamics and platelet transport. For the platelet transport model, we also develop and benchmark the underlying flux-corrected transport algorithm to run in parallel using the FEniCS software suite. We use the numerical tools developed to calibrate and validate an ODE model of extravascular aggregation. With this model, we also benchmark and test the disparity of the fluid and reaction timescales to improve simulation time. These numerical tools provide a framework for future studies in extravascular platelet aggregation and other blood clotting phenomena."],"dc:format.medium":["born digital","doctoral dissertations"],"dc:identifier":["Danes_mines_0052E_11823.pdf","T 8809"],"dc:identifier.uri":["https://hdl.handle.net/11124/173293"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["Colorado School of Mines. Arthur Lakes Library"],"dc:rights":["Copyright of the original work is retained by the author."],"dc:title":["Computational modeling of extravascular platelet aggregation under flow"],"dc:type":["Text"],"thesis:degree_discipline":["Applied Mathematics and Statistics"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"],"thesis:institution_name":["Colorado School of Mines"]},"updated_at":"2026-07-24T01:42:00Z"}