Back to results

Carleton University

Assessing Precision of Metabolite Quantification at 3 Tesla Using ¹H-MRS: Comparative Analysis of PRESS versus Semi-LASER and TE-Averaging

Abstract

dc:description.abstract

Schizophrenia (SZ) is a chronic psychiatric disorder involving multiple brain regions. Heschl’s gyrus (HG) is central to auditory processing, and has been linked to auditory hallucinations, thus relevant for metabolite assessment. The thalamus (TH) is interconnected with various brain regions and is involved in cognition and motivation. Reduced glycine (GLY), which can cause NMDA receptor hypofunction, is believed to contribute to cognitive and negative SZ symptoms, motivating efforts in measuring GLY in the TH. ¹H-MRS at 3 Tesla was used to evaluate metabolite variability and reproducibility in healthy participants by comparing PRESS and semi-LASER in the HG. Semi-LASER produced higher-quality spectra with smaller residuals and improved metabolite estimates. In the TH, TE-averaging was used to enhance GLY while minimizing myo-inositol overlap. Although some metabolites were quantified reliably, GLY exhibited broad, difficult-to-resolve peaks, and poor reproducibility. Further optimization is required for accurate GLY quantification in the TH at 3 Tesla.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vajda, Elias Avraham

Rights

dc:rights
Statement dc:rights
  • Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:carleton.scholaris.ca:20.500.14718/45182

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Vajda, Elias Avraham. Assessing Precision of Metabolite Quantification at 3 Tesla Using ¹H-MRS: Comparative Analysis of PRESS versus Semi-LASER and TE-Averaging. Master's thesis, Carleton University, 2026. https://hdl.handle.net/20.500.14718/45182