Back to results

Carleton University

Design, Fabrication and Calibration of Compliant, Multi-Axis, Fiber-Optic Force/Torque Sensors for Biomechanical Measurements

Abstract

dc:description.abstract

This thesis presents the design, fabrication and characterization of various prototypes of multi-axis, compliant force and torque sensors based on fiber-optic sensing technology, the novel calibration methodologies and the experimental results. A compliant 3-axis, intensity modulated-based, fiber-optic force sensor that simultaneously measures normal and shear forces was designed, prototyped and successfully calibrated. A nonlinear Hammerstein-Weiner model (NLHW) was able to characterize the linear and nonlinear behaviour of this prototype. The optimized results have shown a reduction of over 40% in the Root Mean Square Errors (RMSE) in comparison with the linear estimation models. For biomechanical applications such as ground reaction force and gait measurements, the sensor must be able to measure the complete degree of freedom of any force or torque applied at a certain point. Therefore, a wearable compliant 6-axis force and torque sensor was developed and prototyped. It combines two different force sensing technologies: the 3-axis fiber-optic based force sensor and a pressure sensor matrix. The sensor was capable of accurately measuring the full ground reaction force and moment in real-time with minimal gait disturbance. To enhance the durability, avoid the necessary multi-stage conditioning circuits and their resulting extra electronic components, a 6-axis force and torque sensor that is fully optical has been developed and characterized. The sensor is cost-effective, lightweight and flexible with a large force and torque measurement range suitable for biomechanics and rehabilitation systems. A novel calibration methodology which splits the calibration procedure into two estimation models that work simultaneously as a single calibration system named Least Squares Decision Trees (LSDT). Using LSDT, the estimation speed increased by 55.17% and the RMSE reduced to 0.53%. To improve sensor portability, further reduce size and eliminate electromagnetic interference effects as well as enhance sensor biocompatibility, a non-conductive, electrically passive, fiber Bragg grating (FBG) based normal and shear force sensing elements were designed, fabricated and calibrated. The sensing elements are small size, lightweight and compliant. The results achieved from the proposed calibration method have revealed an improvement from an R-squared value of 93% to 100% when compared to a data obtained using a linear least squares method.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Mechanical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Al-Mai, Osama Moftah Ali

Rights

dc:rights
Statement dc:rights
  • Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:carleton.scholaris.ca:20.500.14718/40645

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Al-Mai, Osama Moftah Ali. Design, Fabrication and Calibration of Compliant, Multi-Axis, Fiber-Optic Force/Torque Sensors for Biomechanical Measurements. Doctoral thesis, Carleton University, 2020. https://hdl.handle.net/20.500.14718/40645